CJ1W-NC414 Omron, CJ1W-NC414 Datasheet - Page 203

no-image

CJ1W-NC414

Manufacturer Part Number
CJ1W-NC414
Description
High Speed Pulse Train 4 Axes
Manufacturer
Omron
Datasheet

Specifications of CJ1W-NC414

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)
JOG/Inching Setting
*1.This setting range is based on the pulse unit.
Inching Width
JOG/ Inching
Speed 1
JOG/ Inching
Speed 2
JOG Acceleration
Time
JOG Deceleration
Time
Parameter name
Inching Width
JOG/Inching Speed
JOG Acceleration Time and JOG Deceleration Time
Set the items that are necessary to perform JOG operation and inching operation.
JOG/inching setting is always valid.
Set the amount of movement per 1 inching operation. If you set the amount of movement to
[0], the axis functions as JOG operation.
You use this parameter as a speed command for JOG operation/inching operation. You can
set one of two speeds, speed 1 and speed 2, and change the speed during operation.
Set the acceleration time and deceleration time of JOG operation and inching operation.
For the JOG acceleration time and JOG deceleration time, [Acceleration/Deceleration Time
Selection] determines the operation.
For details, refer to "Acceleration/Deceleration Setting" on page 5-23 and "Acceleration/
Deceleration Time Selection" on page 5-25.
Depending on [Command Position Unit Setting], an overflow or underflow may occur even if the
command value is within the above range of 0 to 4,000. Take note that the number of pulses must
not exceed the setting range.
Precautions for Correct Use
Set the amount of movement during
inching. If you set this parameter to [0],
the axis operates as JOG.
Set JOG/inching operation speed 1.
Set JOG/inching operation speed 2.
Set the acceleration time of JOG
operation.
Set the deceleration time of JOG
operation.
Function
0 to 250,000
0 to 250,000
0 to 4000
4000000
4000000
Setting
range
1 to
1 to
*1
*1
*1
5-3 Axis Parameters
Command
Command
Command
unit/s
unit/s
Unit
unit
ms
ms
Default
values
10000
1,000
1,000
1000
0
5-42
5

Related parts for CJ1W-NC414