CJ1W-NC414 Omron, CJ1W-NC414 Datasheet - Page 223

no-image

CJ1W-NC414

Manufacturer Part Number
CJ1W-NC414
Description
High Speed Pulse Train 4 Axes
Manufacturer
Omron
Datasheet

Specifications of CJ1W-NC414

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)
Words
n+13
n+14
n+15
PCU error status
PCU error code
Memory Operation
Auxiliary Memory
area
Name
0 to 15
0 to 15
4 to 7
Bit
10
11
12
13
14
15
0
1
2
3
8
9
Restore error
Synchronous data
receive error
Synchronous data
receive warning
Synchronous
processing time
over
Not used
Saved data error
PLC system error
Not used
PCU warning
PCU error
Overall axis error
Overall memory
operation error
Overall error
Bit name
This turns ON upon occurrence of inconsistency
between an internal PCU setting and the
system environment.
This turns ON when missing data occurred at
least twice when you send synchronous data
from the CPU, or a synchronous time monitor
timeout error occurred.
This turns ON (warning) if missing data
occurred at least once when you send
synchronous data from the CPU.
This turns ON when the PCU detects a new
synchronous interrupt in the synchronous cycle
process.
Do not use.
This turns ON when data in the nonvolatile
memory becomes corrupted or data corruption
occurs because the power is cut off while
saving.
This remains ON while an error is input from
outside the system.
Do not use.
This turns ON upon detection of a common
warning-level error within the PCU.
This turns ON upon detection of a common
error within in the PCU.
This turns ON when an axis error occurs.
This turns ON upon occurrence of a memory
operation error.
This turns ON upon occurrence of an error in the
PCU.
This returns an PCU error code.
An input area which you can specify in the PCU
(bits 0 to 15).
5-5 Operating Memory Area
Function
5-62
5