A
Appendix-2 Changes from the Existing PCU
Appendix-9
Control
function
Override
Software limit range
Zone
PLC scan time overrun
with an end refresh
PLC scan time overrun
with an IOWR/IORD
instruction
Time between the
issuance of a start
command from the ladder
program and a pulse
output
Functions and
performances
Manual
operation
Direct
operation
Memory
operation
Memory
operation
data
Number of
settings
Setting
range
JOG, Inching, Origin Search, Origin
Return and MPG
Absolute movement, relative movement
and speed control (You can specify an
interrupt constant-pitch feed for each
control.)
Positioning function: Independent PTP,
linear interpolation, circular
interpolation, speed control, interrupt
feeding
End pattern: Individual, automatic or
continuous pattern
Set the elements below as a set of
memory operation data.
Set it to 0.01% to 500.00% in units of
0.01%.
-2,147,483,647 to 2,147,483,646 pulses -1,073,741,823 to 1,073,741,823
3/axis
-2,147,483,648 to 2,147,483,647 pulses -1,073,741,823 to 1,073,741,823
0.2 to 0.5 ms or less/unit
0.1 to 0.3 ms or less/instruction *1
0.1 ms or less (During high-speed PTP
start)
1 to 2 ms or less (During direct operation
start)
Sequence (such as command and end
pattern)
You can set up a maximum of 500 × 4
tasks as memory operation data.
Command position
Command position
Command speed
Acceleration time
Deceleration time
Dwell timer
CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)
CJ1W-NC2x4/4x4
*1
JOG, Origin Search, Origin
Return
Absolute movement, relative
movement, speed control and
interrupt feeding
Positioning function: linear
interpolation, interrupt feeding
End pattern: Individual,
automatic or continuous pattern
Set the data below individually.
Set it to 1% to 999% in units of
1%.
pulses
3/axis
pulses
0.5 ms or less/1 unit
1 ms or less/instruction
Minimum of 2 ms or less
axis
Sequence data 100 x 4 tasks
Command position data 100/
Command speed data100/axis
Acceleration time data 9/axis
Deceleration time data 9/axis
Dwell timer data 19/axis
CJ1W-NC1x3/2x3/4x3