CJ1W-NC414 Omron, CJ1W-NC414 Datasheet - Page 556

no-image

CJ1W-NC414

Manufacturer Part Number
CJ1W-NC414
Description
High Speed Pulse Train 4 Axes
Manufacturer
Omron
Datasheet

Specifications of CJ1W-NC414

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
12
12-8 Error Reset
12-47
If you set the first word in the Axis Status area to [C], the allocations in the table below apply.
If you set the first word in Memory Operation Status Memory area to [E], the allocations in the
table below apply.
Axis Busy
Sensor Error
Servo Error
Execution Error
Axis Warning
Axis Error
Memory Operation
Busy
Memory Operation
Execution Error
Memory Operation
Warning
Memory Operation
Error
Name
Name
Memory Operation Status Memory area
Task 1
Axis 1
C+2
C+5
E+1
E+2
Operation Memory area
CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)
Task 2
Axis 2
C+15
C+18
E+7
E+8
Task 3
Axis 3
C+28
C+31
E+13
E+14
Task 4
Axis 4
C+41
C+44
E+19
E+20
Bit
Bit
00
08
09
10
11
12
00
10
11
12
1: Busy
This turns ON when an
external sensor for the
emergency stop input
or limit input generates
an error.
This turns ON when the
outside the system
notifies a driver alarm
input or other error.
This turns ON when the
axis function generates
an operation error.
This turns ON when a
warning occurs.
This turns ON when an
axis error occurs.
This remains ON while
a task configuration
axis is busy or task
function is in progress.
This turns ON when the
task function generates
an operation error.
This turns ON when a
warning occurs.
This turns ON upon
occurrence of a
memory operation
error.
Description
Description