CJ1W-NC414 Omron, CJ1W-NC414 Datasheet - Page 316

no-image

CJ1W-NC414

Manufacturer Part Number
CJ1W-NC414
Description
High Speed Pulse Train 4 Axes
Manufacturer
Omron
Datasheet

Specifications of CJ1W-NC414

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
7
7-3 Memory Operation
7-15
Commands
NOP
JUMP
Sequence
[Command] is a data that allocates the attribute each sequence data has.
2 types of [Command] data are available: data with sequence attribute and data with operation
attribute.
Sequence commands have the 2 functions below:
For the memory operation condition data, refer to "Memory Operation Condition Data" on page
5-98.
Regarded as a comment.
Nothing happens and the sequence number changes to the next one.
Sequence data for JUMP instruction.
If you set a JUMP instruction under [Command], you can set the 4 types of sequence data
below.
The program jumps to the specified sequence number under the specified condition.
If the condition is False, the sequence number changes to the next one. If it is True, the
sequence number changes to the specified number.
Command
Sequence start
condition
JUMP/ Repeat
conditions
JUMP destination
sequence No.
Function to forcibly turn ON/OFF the contact information to be output to the CPU and outside the
continuous operation.
PCU.
Function to branch and repeat the sequences according to the control conditions during
Data name
Select [JUMP].
Use a memory operation condition data number to set the starting condition.
You can also set this item to no condition.
Set the memory operation condition data number. You can also set this item to
no condition.
Set the sequence number for the JUMP destination.