CJ1W-NC414 Omron, CJ1W-NC414 Datasheet - Page 98

no-image

CJ1W-NC414

Manufacturer Part Number
CJ1W-NC414
Description
High Speed Pulse Train 4 Axes
Manufacturer
Omron
Datasheet

Specifications of CJ1W-NC414

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
3
3-2 JOG Operation
3-5
*1. This setting range is based on the pulse unit.
*2. For the command unit, refer to "Command Position Unit Setting" on page 5-29.
Inching Width
JOG/Inching Speed
JOG Acceleration Time and JOG Deceleration Time
Inching Width
JOG/ Inching
Speed 1
JOG/ Inching
Speed 2
JOG Acceleration
Time
JOG Deceleration
Time
Parameter name
JOG/Inching Setting
In the setting example, you set only the minimum required data. This section explains [JOG/
Inching Setting] under [Axis Parameter] in details.
Set the amount of movement per one inching operation. If you set the amount of movement to
[0], the axis functions as JOG operation.
Use this parameter as a speed command for JOG operation/inching operation. You can set
two speeds, speed 1 and speed 2, and change the speed during operation.
Set the acceleration time and deceleration time of JOG operation and inching operation.
For the JOG acceleration time and JOG deceleration time, [Acceleration/ Deceleration Time
Selection] determines their changing patterns.
For details, refer to "Acceleration/Deceleration Setting" on page 5-23 and "Acceleration/
Deceleration Time Selection" on page 5-25.
The previous setting example did not mention the command unit. However, most axis parameters
All setting ranges are based on the pulse unit.
use default values, so the command unit is set to one pulse.
Reference
Set the amount of movement during
inching. If you set this parameter to [0],
the axis operates as JOG.
Set JOG/inching speed 1.
Set JOG/inching speed 2.
Set the acceleration time of JOG
operation.
Set the deceleration time of JOG
operation.
Function
CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)
1 to 4000000
1 to 4000000
Setting range
0 to 250000
0 to 250000
0 to 4000
*1
*1
*1
Command unit
Command unit
Command unit
Unit
ms
ms
/s
/s
*2
*2
*2
Default
10000
value
1000
1000
1000
0

Related parts for CJ1W-NC414