Specifications of CJ1W-NC414

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
9
9-4 Torque Limit
9-21
Note. For details on the torque limit function of the Servo Drive, refer to the User's Manual for each model. In the
W-series
(R88D-WTx)
SMARTSTEP2 Series
(R7D-BPx)
automatic control of torque limit output during Origin Search, the output signal turns ON when a torque
limit is applied. Set an appropriate torque limit value so as to match the aforementioned operation when
the torque limit output turns ON with that of the holding direction.
Servo Drive
The Forward External Torque
Limit (Pn404) or Reverse External
Torque Limit (Pn405) does not
limit the motor output torque.
The Torque Limit (Pn5E) limits the
motor output torque.
Torque limit output OFF
CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)
When the PCL signal is ON: The
Forward External Torque Limit (Pn404)
limits the motor output torque in
forward direction.
When the NCL signal is ON: The Reverse
External Torque Limit (Pn405) limits the
motor output torque in reverse direction.
No. 2 Torque Limit (Pn71) limits the
motor output torque.
Torque limit output ON