CJ1W-NC414 Omron, CJ1W-NC414 Datasheet - Page 215

no-image

CJ1W-NC414

Manufacturer Part Number
CJ1W-NC414
Description
High Speed Pulse Train 4 Axes
Manufacturer
Omron
Datasheet

Specifications of CJ1W-NC414

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)
Teaching Setting
Interpolation Axis Stop Method
Teaching Object
Interpolation Axis
Stop Method
Parameter name
Parameter name
Select the target position data for task teaching.
Teaching setting is always enabled.
Set the stop method which will apply to other axes upon issuance of a servo unlock, Error
Counter Reset or deceleration stop command to each individual interpolation axis during
memory operation.
Interpolation axis stop method becomes enabled at power supply ON, restart, or setup.
If you set [4: RUN Output OFF] when you are not using the RUN output, immediate stop is applied.
Precautions for Correct Use
Select the target position data for
teaching.
0: Command position, 1: Feedback
Position
0: Immediate stop (Deviation pulse stop)
1: Deceleration stop
4: RUN OFF of pulse output (Free run
5: Interpolation path deceleration stop
stop)
Function
Function
5-4 Memory Operation Parameter
Setting
Setting
range
range
0 to 1
0 to 5
Unit
Unit
Default
Default
values
values
0
0
5-54
5

Related parts for CJ1W-NC414