CJ1W-NC414 Omron, CJ1W-NC414 Datasheet - Page 550

no-image

CJ1W-NC414

Manufacturer Part Number
CJ1W-NC414
Description
High Speed Pulse Train 4 Axes
Manufacturer
Omron
Datasheet

Specifications of CJ1W-NC414

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
12
12-6 Error Code List
12-41
Category
Each
task
Each
axis
Interpolation
Movement
Amount Overflow
Error Between
Axes Over
Synchronous
Feeding
Command
Position Data
Setting Invalid
Item name
Error code
6C04
6C20
6E01
The amount of movement by
interpolation operation
exceeded the usable range
during linear interpolation or
circular interpolation
command.
The error between the
specified interpolation axes
exceeded the set value
during linear interpolation.
The setting of synchronous
feeding command position
data is invalid.
CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)
Cause
Check the set value of the command
position and then execute an error reset.
If this error occurs, the PCU decelerates
all configuration axes of the applicable
task to a stop.
Remove the cause of the deviation
between the interpolation axes, and then
execute an error reset.
If this error occurs, the PCU decelerates
all configuration axes of the applicable
task to a stop.
Check the setting of synchronous
feeding command position data and then
execute an error reset.
Release method

Related parts for CJ1W-NC414