CJ1W-NC414 Omron, CJ1W-NC414 Datasheet - Page 315

no-image

CJ1W-NC414

Manufacturer Part Number
CJ1W-NC414
Description
High Speed Pulse Train 4 Axes
Manufacturer
Omron
Datasheet

Specifications of CJ1W-NC414

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
7-3 Memory Operation
CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)
Starting Memory Operation
Memory Operation Execution
Memory Operation Independent Start Execution
This section explains memory operation.
When you issue a memory operation start command, specify the sequence number first.
2 starting methods below are available:
(1) Turn memory operation from OFF to ON.
(2) Turn memory operation independent start from OFF to ON.
For a start via [Memory Operation], after you execute the started sequence, automatically
execute the next sequence number.
Execution continues until [END] is found in the sequence data [Command].
If you select [Individual] under [End Pattern], however, operation stops temporarily.
To execute the subsequent sequence number, you must start [Memory Operation] again.
If [JUMP] to another sequence number or [FOR to NEXT] loop does not occur until sequence
No. 500, you can assume that [END] has been executed after sequence No. 500.
Also, an error occurs if you have not set sequence number when [Memory Operation] starts.
For a start via [Memory Operation Independent Start], perform all operations as [Individual] for
[End Pattern], regardless of sequence data designation.
Use [Memory Operation Independent Start] for debugging by step execution.
Perform operation according to the specified sequence number, after which [Executing
Sequence No.] is updated based on the execution result and then the operation ends.
In normal operation, use [Memory Operation].
To perform memory operation for the first time, you must set a sequence number and turn ON the
sequence number enable bit.
position preset.
sequence number has not been set.
execution sequence number, you must set the sequence number again and turn ON the sequence
number enable bit.
An error occurs if you start memory operation without specifying a sequence number when a
When you start memory operation based on a sequence number which is different from the
The sequence number is cleared upon servo lock, Origin Search, Origin Return, or present
Reference
7-3 Memory Operation
7-14