DF2505BR26DV Renesas Electronics America, DF2505BR26DV Datasheet - Page 482

IC H8S/2505 MCU FLASH 176-LFBGA

DF2505BR26DV

Manufacturer Part Number
DF2505BR26DV
Description
IC H8S/2505 MCU FLASH 176-LFBGA
Manufacturer
Renesas Electronics America
Series
H8® H8S/2500r
Datasheets

Specifications of DF2505BR26DV

Core Processor
H8S/2000
Core Size
16-Bit
Speed
26MHz
Connectivity
I²C, SCI
Peripherals
POR, PWM, WDT
Number Of I /o
104
Program Memory Size
384KB (384K x 8)
Program Memory Type
FLASH
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 16x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
176-LFBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF2505BR26DV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 13 Serial Communication Interface (SCI)
Rev. 6.00 Sep. 24, 2009 Page 434 of 928
REJ09B0099-0600
No
No
Read receive data in RDR, and
clear RDRF flag in SSR to 0
Read RDRF flag in SSR
Clear RE bit in SCR to 0
Read ORER, PER, and
PER FER ORER = 1
All data received?
FER flags in SSR
Start reception
Initialization
RDRF = 1
Figure 13.9 Sample Serial Reception Data Flowchart (1)
<End>
Yes
Yes
No
(Continued on next page)
Error processing
Yes
[1]
[2]
[4]
[5]
[3]
[1] SCI initialization:
[2] [3] Receive error processing and break
[4] SCI status check and receive data read:
[5] Serial reception continuation procedure:
Note: * The case, where the RDRF flag is
The RxD pin is automatically
designated as the receive data input
pin.
detection:
If a receive error occurs, read the
ORER, PER, and FER flags in SSR to
identify the error. After performing the
appropriate error processing, ensure
that the ORER, PER, and FER flags are
all cleared to 0. Reception cannot be
resumed if any of these flags are set to
1. In the case of a framing error, a
break can be detected by reading the
value of the input port corresponding to
the RxD pin.
Read SSR and check that RDRF = 1,
then read the receive data in RDR and
clear the RDRF flag to 0. Transition of
the RDRF flag from 0 to 1 can also be
identified by an RXI interrupt.
To continue serial reception, before the
stop bit for the current frame is
received, read the RDRF flag, read
RDR, and clear the RDRF flag to 0.
The RDRF flag is cleared automatically
when DTC* is activated by an RXI
interrupt and the RDR value is read.
automatically cleared by DTC,
occurs only when the DISEL bit in DTC is 0
with the transfer counter other than 0.
Therefore, when the DISEL bit is 1, or
both the DISEL bit and the transfer counter are 0,
give the CPU an instruction to clear the RDRF flag.

Related parts for DF2505BR26DV