DF2505BR26DV Renesas Electronics America, DF2505BR26DV Datasheet - Page 496

IC H8S/2505 MCU FLASH 176-LFBGA

DF2505BR26DV

Manufacturer Part Number
DF2505BR26DV
Description
IC H8S/2505 MCU FLASH 176-LFBGA
Manufacturer
Renesas Electronics America
Series
H8® H8S/2500r
Datasheets

Specifications of DF2505BR26DV

Core Processor
H8S/2000
Core Size
16-Bit
Speed
26MHz
Connectivity
I²C, SCI
Peripherals
POR, PWM, WDT
Number Of I /o
104
Program Memory Size
384KB (384K x 8)
Program Memory Type
FLASH
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 16x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
176-LFBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF2505BR26DV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 13 Serial Communication Interface (SCI)
Rev. 6.00 Sep. 24, 2009 Page 448 of 928
REJ09B0099-0600
Write transmit data to TDR and
clear TDRE flag in SSR to 0
Read TDRE flag in SSR
Read TEND flag in SSR
Clear TE bit in SCR to 0
All data transmitted?
Start transmission
Initialization
TDRE = 1
TEND = 1
<End>
Yes
Yes
Yes
Figure 13.17 Sample Serial Transmission Flowchart
No
No
No
[3]
[2]
[1]
[1] SCI initialization:
[2] SCI status check and transmit data
[3] Serial transmission continuation
Note: * The case, where the TDRE flag is
The TxD pin is automatically
designated as the transmit data output
pin.
write:
Read SSR and check that the TDRE
flag is set to 1, then write transmit data
to TDR and clear the TDRE flag to 0.
procedure:
To continue serial transmission, be
sure to read 1 from the TDRE flag to
confirm that writing is possible, then
write data to TDR, and then clear the
TDRE flag to 0.
Checking and clearing of the TDRE
flag is automatic when the DTC* is
activated by a transmit data empty
interrupt (TXI) request and data is
written to TDR.
automatically cleared by DTC,
occurs only when the DISEL bit in DTC is 0
with the transfer counter other than 0.
Therefore, when the DISEL bit is 1, or
both the DISEL bit and the transfer counter are 0,
give the CPU an instruction to clear the TDRE flag.

Related parts for DF2505BR26DV