mt9072av2 Zarlink Semiconductor, mt9072av2 Datasheet - Page 124

no-image

mt9072av2

Manufacturer Part Number
mt9072av2
Description
Octal T1/e1/j1 Framer
Manufacturer
Zarlink Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MT9072AV2
Manufacturer:
TRIQUINT
Quantity:
56
Part Number:
MT9072AV2
Manufacturer:
ZARLINK
Quantity:
20 000
15-10
15-10
9-8
7-0
Bit
9-8
7-0
Bit
TXLAC7-0
TXLDC7-0
TXLACL
TXLDCL
Name
(0000
0001)
Name
(0000
1001)
(00)
1-0
(01)
1-0
#
#
not used
Transmit Loop Activate Code Length. These 2 bits define the length of the transmit loop up
code.
00-Code length is 5 bits
01-Code length is 6 or 3 bits
10-Code length is 7 bits
11-Code length is 8 or 4 bits
Note: if 3 bit code or 4 bit code is required the bits have to be repeated in TXLDC7-0.
For instance if the code 1011 is desired, the TXLAC has to be set to 10111011 and the length
TXLACL to 11.
Transmit Loop Activate Code. This byte specifies the inband loopup code to be transmitted.
The default values are the T1.403 values for Loop Activate Code.
not used
Transmit Loop Deactivate Code Length. These 2 bits define the length of the transmit
loop down code.
00-Code length is 5 bits
01-Code length is 6 or 3 bits
10-Code length is 7 bits
11-Code length is 8 or 4 bits
Note if 3 bit code or 4 bit code is required the bits have to be repeated in the TXLDC7-0. For
instance if the code 1011 is desired, the TXLDC has to be set to 10111011 and TxDLCL to 11
Transmit Loop Deactivate Code. This byte specifies the inband loopdown code to be
transmitted. If 001 is to be transmitted as a loopdown code; the register has to programmed
to a value of XX001001and the length (TXLDL has to be 01).The default values are the
T1.403 values for Loop Deactivate Code.
Table 76 - Transmit Loop Deactivate Code Register(Y0E) (T1)
Table 75 - Transmit Loop Activate Code Register(Y0D) (T1)
Zarlink Semiconductor Inc.
MT9072
Functional Description
124
Functional Description
Data Sheet