1. The ST-BUS Analyser can be used in continuous acquisition mode without any problem (Register 901, bit 0 is set). If the
ST-BUS analyser is used in the single mode (Register 901, bit 0 is cleared) an interrupt generated cannot be cleared and
the MT9072 has to be reset.
Bit
15-11
15
14
13
10-8
7-6
4-2
Bit
5
1
0
Name
F3HM
F3RM
F3EM
(0)
(0)
(0)
CHANNUM
STBUFEN
CONTSIN
STRNUM
(00000)
(00000)
FNUM
CHUP
Name
(000)
(2:0)
(0)
(0)
(0)
#
Framer 3 HDLC Mask. This is the mask bit for the F3HVS status bit in the Interrupt Vector
Register(address 910). If this mask bit is one, the corresponding Interrupt Vector status bit will
remain inactive (zero). If this mask bit is zero, the corresponding Interrupt Vector status bit will
function normally.
Framer 3 Elastic Mask. This is the mask bit for the F3EVS status bit in the Interrupt Vector
Register (address 910). If this mask bit is one, the corresponding Interrupt Vector status bit will
remain inactive (zero). If this mask bit is zero, the corresponding Interrupt Vector status bit will
function normally.
Framer 3 Rx Line Mask. This is the mask bit for the F3RVS status bit in the Interrupt Vector
Register (address 910). If this mask bit is one, the corresponding Interrupt Vector status bit will
remain inactive (zero). If this mask bit is zero, the corresponding Interrupt Vector status bit will
function normally.
Table 121 - Interrupt Vector 1 Mask Register (Address 902) (T1)
not used.
Channel Number.These 5 bits determine the channel that is used for updating of the
ST-Bus Analyzer buffer.
Stream Number. These 5 bits determine the streams that will be used as the source data
for the ST-Bus Analyzer buffer.
00: DSTi
01: DSTo
10: CSTi
11: CSTo
ST-BUS Analyser Buffer Enable. Setting this bit enables the ST-BUS Analyser Buffer
update. When the user reads the buffer (920-93F), this bit must be 0. Any reads of the
buffer while this bit is set does not ensure correct data being read.
Framer Number 0 to 7
Channel Update. If 0 the update of the memory is at frame rate for a given channel. The
channel selected for update is provided by the ChanNum bits of this register. If set the
complete frame (channels 0 to 32) are updated to the buffer.
Continuous Single. If set to 1 the ST-BUS Analyzer buffer is updated continuously. If set
to zero the buffer is updated once and stopped. An optional interrupt can be generated
once the buffer is full
Table 120 - Global Control1 Register (R/W Address 901) (T1)