HD6417751RF240V Renesas Electronics America, HD6417751RF240V Datasheet - Page 228

MPU 1.5/3.3V 0K PB-FREE 256-QFP

HD6417751RF240V

Manufacturer Part Number
HD6417751RF240V
Description
MPU 1.5/3.3V 0K PB-FREE 256-QFP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7750r
Datasheet

Specifications of HD6417751RF240V

Core Processor
SH-4
Core Size
32-Bit
Speed
240MHz
Connectivity
EBI/EMI, FIFO, SCI, SmartCard
Peripherals
DMA, POR, WDT
Number Of I /o
39
Program Memory Type
ROMless
Ram Size
48K x 8
Voltage - Supply (vcc/vdd)
1.4 V ~ 1.6 V
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
256-QFP Exposed Pad, 256-eQFP, 256-HQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-
Data Converters
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417751RF240V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
4. Caches
4.6.3
The OC address array is allocated to addresses H'F400 0000 to H'F4FF FFFF in the P4 area. An
address array access requires a 32-bit address field specification (when reading or writing) and a
32-bit data field specification. The way and entry to be accessed are specified in the address field,
and the write tag, U bit, and V bit are specified in the data field.
In the address field, bits [31:24] have the value H'F4 indicating the OC address array, the way is
specified by bit [14], and the entry is specified by bits [13:5]. CCR.OIX has no effect on this entry
specification. The OC address array access in RAM mode (CCR.ORA = 1) is performed only to
cache, and bit [13] specifies the way. For details on address allocation, see section 4.6.5, Summary
of Memory-Mapped OC Addresses. Address field bit [3], that is the association bit (A bit),
specifies whether or not association is performed when writing to the OC address array. As only
longword access is used, 0 should be specified for address field bits [1:0].
In the data field, the tag is indicated by bits [31:10], the U bit by bit [1], and the V bit by bit [0].
As the OC address array tag is 19 bits in length, data field bits [31:29] are not used in the case of a
write in which association is not performed. Data field bits [31:29] are used for the virtual address
specification only in the case of a write in which association is performed.
The following three kinds of operation can be used on the OC address array:
1. OC address array read
2. OC address array write (non-associative)
3. OC address array write (associative)
Rev.4.00 Oct. 10, 2008 Page 128 of 1122
REJ09B0370-0400
The tag, U bit, and V bit are read into the data field from the OC entry corresponding to the
way and entry set in the address field. In a read, associative operation is not performed
regardless of whether the association bit specified in the address field is 1 or 0.
The tag, U bit, and V bit specified in the data field are written to the OC entry corresponding to
the way and entry set in the address field. The A bit in the address field should be cleared to 0.
When a write is performed to a cache line for which the U bit and V bit are both 1, after write-
back of that cache line, the tag, U bit, and V bit specified in the data field are written.
When a write is performed with the A bit in the address field set to 1, each way's tag stored in
the entry specified in the address field is compared with the tag specified in the data field. The
way number set in bit [14] is ignored. If the MMU is enabled at this time, comparison is
performed after the virtual address specified by data field bits [31:10] has been translated to a
physical address using the UTLB. If the addresses match and the V bit in that way is 1, the U
bit and V bit specified in the data field are written into the OC entry. This operation is used to
invalidate a specific OC entry. In other cases, no operation is performed. If the OC entry U bit
is 1, and 0 is written to the V bit or to the U bit, write-back is performed. If a UTLB miss
OC Address Array

Related parts for HD6417751RF240V