Install surge killers for loads that have induction coils, such as relays, solenoids, brakes, clutches,
etc. The following table shows types of surge killers and recommended products.
Note Thyristors and varistors are made by the following companies. Refer to manufacturers docu-
When selecting contactors, take into consideration the circuit’s inrush current and the maximum
momentary current. The Servo Driver inrush current is covered in the preceding explanation of no-
fuse-breaker selection, and the maximum momentary current is approximately twice the rated cur-
rent. The following table shows the recommended contactors.
Select leakage breakers designed for inverters.
Since switching takes place inside the Servo Drivers, harmonic current leaks from the armature of
the motor. With inverter leakage breakers, harmonic current is not detected, preventing the breaker
from operating due to leakage current.
When selecting leakage breakers, remember to also add the leakage current from devices other than
the Servomotor, such as machines using a switching power supply, noise filters, inverters, and so on.
For details on leakage breakers, refer to the manufacturer’s catalog.
3-34
System Design and Installation
Diode
Thyristor
or
Varistor
Capacitor
+ resistor
OMRON
Surge Killers
Contactors
Leakage Breakers
Type
Maker
mentation for operating details.Thyristors: Ishizuka Electronics Co.
Varistors: Ishizuka Electronics Co., Matsushita Electric Industrial Co.
Diodes are relatively small devices such as relays used
for loads when reset time is not an issue. The reset time
is increased because the surge voltage is the lowest
when power is cut off. Used for 24/48-V DC systems.
Thyristor and varistor are used for loads when induction
coils are large, as in electromagnetic brakes, solenoids,
etc., and when reset time is an issue. The surge voltage
when power is cut off is approximately 1.5 times that of
the varistor.
Use capacitors and resistors for vibration absorption of
surge when power is cut off. The reset time can be short-
ened by proper selection of the capacitor or resistor.
LC1-D093A60
LC1D25106
LC1D40116
LC1D50116
LC1-D093A60
LP1D25106
LP1D40116
LP1D50116
Model
Features
11 A
26 A
35 A
50 A
11 A
26 A
35 A
50 A
Rated current
200 V AC
24 V DC
Coil voltage
Use a fast-recovery diode with a short
reverse recovery time.
Fuji Electric Co., ERB44-06 or equiv-
alent
Select varistor voltage as follows:
24-V DC system: 39 V
100-V DC system: 200 V
100-V AC system: 270 V
200-V AC system: 470 V
Okaya Electric Industries Co., Ltd.
CR-50500 0.5 µ F-50 Ω
CRE-50500 0.5 µ F-50 Ω
S2-A-0 0.2 µ F-500 Ω
Recommended products