R7M-AP10030-BS1 Omron, R7M-AP10030-BS1 Datasheet - Page 213

no-image

R7M-AP10030-BS1

Manufacturer Part Number
R7M-AP10030-BS1
Description
MOTORSERVO FLAT 100W W/BRAKE&KEY
Manufacturer
Omron
Datasheet

Specifications of R7M-AP10030-BS1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R7MAP10030BS1
Operation
4-7-5 Position Command Filter Function
• Perform soft start processing for the command pulses using the selected filter to gently accelerate
• Select the filter characteristics using Pn207.0 (position command filter selection).
• When Pn204 (position command filter time constant 1) is selected, acceleration and deceleration
• When Pn208 (position command filter time constant 2) is selected, acceleration and deceleration
• This function is effective in the following cases:
Note If not using the position command filter function, set each to 0 (i.e., the default setting).
• The characteristics for each filter are shown below.
• Servomotor acceleration and deceleration are delayed further than the characteristics shown below
Pn207.0
Pn204
Pn208
Parameter No.
and decelerate.
are performed using the primary filter (exponentiation function).
are linear.
due to position loop gain delay.
Primary Filter
Functions
Operation
There is no acceleration/deceleration function in the command pulse (controller).
The command pulse frequency changes rapidly, causing the machinery to vibrate during acceler-
ation and deceleration.
The electronic gear setting is high (G1/G2 ≥ 10).
Acceleration: 2/Kp (s); Deceleration: 3/Kp (s); Kp: Position loop gain (Pn102)
Parameters Requiring Settings
Input frequency x 0.63
Input frequency x 0.37
Select position control filter Select either primary filter (setting: 0), or linear acceleration
Position control filter time
constant 1 (primary filter)
Position control filter time
constant 2 (linear acceler-
ation and deceleration)
Command pulse
input frequency
Parameter name
Speed
Pn204
and deceleration (setting: 1).
Enabled when Pn207.0 = 0. Be sure to set the primary filter
time constant (setting range = 0 to 6400 ( × 0.01 ms)).
Enabled when Pn207.0 = 1. Be sure to set the acceleration and
deceleration times (setting range = 0 to 6400 ( × 0.01 ms)).
Pn204
Explanation
Time
Chapter 4
4-31

Related parts for R7M-AP10030-BS1