R7M-AP10030-BS1 Omron, R7M-AP10030-BS1 Datasheet - Page 237

no-image

R7M-AP10030-BS1

Manufacturer Part Number
R7M-AP10030-BS1
Description
MOTORSERVO FLAT 100W W/BRAKE&KEY
Manufacturer
Omron
Datasheet

Specifications of R7M-AP10030-BS1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R7MAP10030BS1
Appendix
Note 1. Incorrect signal wiring can cause damage to Units and the Servo Driver.
Note 2. Leave unused signal lines open and do not wire them.
Note 3. Use mode 2 for origin search.
Note 4. Use the 5-V DC power supply for command pulse signals as a dedicated power supply.
Note 5. The diode recommended for surge absorption is the ERB44-02 (Fuji Electric) or equivalent.
Note 6. Do not use the 24-V DC brake power supply for the 24-V DC control power.
Connection Example 4: Connecting to SYSMAC CJ1W-NC133/233/433
CJ1W-NC133/233/433
X-axis
output
5-V power supply for pulse output
5-V ground for pulse output
pulse
X-axis dev. cntr. reset output
X-axis origin input (24 V)
X-axis origin common
X-axis positioning completed input
24-V power supply for output
0-V power supply for output
Input common
X-axis external interrupt input
X-axis origin proximity input
X-axis CCW limit input
X-axis CW limit input
X-axis emerg. stop input
CW (+) output
CW (−) output
CCW (+) output
CCW (−) output
Contents
Single-phase 200/230 V AC 50/60 Hz
Single-phase 100/115 V AC 50/60 Hz
A10
A13
A12
A11
A20
A15
A17
A19
A18
A16
No.
A4
A3
A5
A6
A7
A8
A1
A2
5 V DC
24 V DC
Class D ground
(Class 3 ground:
100 Ω or less)
24 V DC
R88A-CPU@S
R
T
X1
XB
X1
NFB
R7D-AP@
Shell
33
32
13
14
18
10
35
34
1
2
3
4
5
6
8
7
Main-circuit power supply
CN1
ALMCOM
+ECRST
−ECRST
+24VIN
RESET
+CCW
−CCW
ZCOM
OGND
BKIR
+CW
−CW
RUN
ALM
INP
FG
Z
OFF
X1
MC
ON
L1C
L2C
+
+
TB
L1
L2
B1
B2
W
+
U
V
CN2
1
2
24 V DC
X1
Red
White
Blue
Green/
Yellow
MC
XB
SUP
MC
PL
Servomotor cable
• Integrated
• Separate
DC reactor
(power and
encoder)
Main-circuit contact
Surge killer
Servo error display
R7M-A@
M
E
B
Chapter 6
6-5

Related parts for R7M-AP10030-BS1