R7M-AP10030-BS1 Omron, R7M-AP10030-BS1 Datasheet - Page 188

no-image

R7M-AP10030-BS1

Manufacturer Part Number
R7M-AP10030-BS1
Description
MOTORSERVO FLAT 100W W/BRAKE&KEY
Manufacturer
Omron
Datasheet

Specifications of R7M-AP10030-BS1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R7MAP10030BS1
Switch 2 sets dynamic brake operation. When dynamic braking is enabled, the Servomotor is
stopped rapidly when the RUN command is turned OFF or when an alarm occurs.
Note Regardless of the setting, when the main-circuit power supply or control-circuit power supply is
The online autotuning switch function adjusts the gain automatically during operation.
Note Operation of the online autotuning switch is described in 4-5 Gain Adjustments.
4-6
Operation
OFF
ON
OFF
ON
Dynamic Brake Setting (Switch 2)
Online Autotuning Switch
Switch 2
Switch 1
turned OFF, dynamic braking will operate.
Dynamic braking is disabled. (When the RUN command is turned OFF or when an alarm
occurs, the Servomotor will coast to a stop.)
Dynamic braking is enabled.
Ends online autotuning and stores the tuning results to the Servo Driver’s internal inertia
ratio parameter (Pn103).
Executes online autotuning.
Online autotuning switch
Dynamic brake setting
Chapter 4