ATM Physical Interface (PHY) Devices
0x15—RXK2 (Receive K2 Overhead Status Register)
The RXK2 register controls the K2 byte in the transport overhead. The K1 byte and bits 0–5 of the K2 byte are
allocated for Automatic Protection Switching (APS) signaling between line level entities. These bytes are
defined only for the first STS-1 of the STS-3c signal.
These bytes are defined only for the first STS-1 of the STS-3c signal.
0x46—RXLIN (Receive Line Overhead Status Register)
The RXLIN register contains status information for the receiver Line Overhead.
28250-DSH-002-C
NOTE(S):
(1)
(2)
Bits 6–8 of the K2 byte are allocated for Alarm Indication Signal (AIS) and Remote Defect Indicator (RDI).
Bit
Bit
This status reflects the current state of the circuit.
This status shows an event that has occurred since the register was last read.
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
Default
Default
x
x
x
x
x
x
0
0
x
x
x
x
x
x
x
x
EnRxSecDL
EnRxLinDL
RDI-L
AIS-L
B2Err
REI-L
RxK2[1]
RxK2[2]
RxK2[3]
RxK2[4]
RxK2[5]
RxK2[6]
RxK2[7]
RxK2[8]
K1K2
LOP
Name
Name
(1)
(2)
(1)
(1)
(2)
(2)
When a logic 1 is read, this bit indicates that a Loss of Pointer condition exists.
When a logic 1 is read, this bit indicates that an K1K2 Value Change was received.
When a logic 1 is read, this bit indicates that an AIS-L condition exists.
When a logic 1 is read, this bit indicates that an RDI-L condition exists.
When a logic 1 is read, this bit indicates that a Line BIP Error was received.
When a logic 1 is read, this bit indicates that a REI-L Error was received.
When written to a logic 1, this bit enables the Receive D4-12 bytes of the Data Link.
When written to a logic 1, this bit enables the Receive D1/D2/D3 bytes of the Data Link.
Receive value for K2 Overhead Octet—bit 1 (MSB)
Receive value for K2 Overhead Octet—bit 2
Receive value for K2 Overhead Octet—bit 3
Receive value for K2 Overhead Octet—bit 4
Receive value for K2 Overhead Octet—bit 5
Receive value for K2 Overhead Octet—bit 6
Receive value for K2 Overhead Octet—bit 7
Receive value for K2 Overhead Octet—bit 8 (LSB)