DF2398TE20 Renesas Electronics America, DF2398TE20 Datasheet - Page 405

IC H8S MCU FLASH 256K 120TQFP

DF2398TE20

Manufacturer Part Number
DF2398TE20
Description
IC H8S MCU FLASH 256K 120TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheets

Specifications of DF2398TE20

Core Processor
H8S/2000
Core Size
16-Bit
Speed
20MHz
Connectivity
SCI, SmartCard
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
87
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
120-TQFP, 120-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Other names
HD64F2398TE20
HD64F2398TE20

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF2398TE20V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Input Capture Function: The TCNT value can be transferred to TGR on detection of the TIOC pin input edge.
Rising edge, falling edge, or both edges can be selected as the detected edge. For channels 0, 1, 3, and 4, it is also possible
to specify another channel’s counter input clock or compare match signal as the input capture source.
Note: When another channel’s counter input clock is used as the input capture input for channels 0 and 3, ø/1 should not
Figure 10-11 shows an example of toggle output.
In this example TCNT has been designated as a periodic counter (with counter clearing performed by compare match
B), and settings have been made so that output is toggled by both compare match A and compare match B.
Example of input capture operation setting procedure
Figure 10-12 shows an example of the input capture operation setting procedure.
be selected as the counter input clock used for input capture input. Input capture will not be generated if ø/1 is
selected.
H'FFFF
TGRB
TGRA
H'0000
TIOCB
TIOCA
TCNT value
<Input capture operation>
Select input capture input
Figure 10-12 Example of Input Capture Operation Setting Procedure
Input selection
Start count
Figure 10-11 Example of Toggle Output Operation
Counter cleared by TGRB compare match
[1]
[2]
[1] Designate TGR as an input capture register by
[2] Set the CST bit in TSTR to 1 to start the count
means of TIOR, and select rising edge, falling
edge, or both edges as the input capture source
and input signal edge.
operation.
Rev.6.00 Oct.28.2004 page 375 of 1016
Toggle output
Toggle output
Time
REJ09B0138-0600H