HD6417320 RENESAS [Renesas Technology Corp], HD6417320 Datasheet - Page 718

no-image

HD6417320

Manufacturer Part Number
HD6417320
Description
Renesas 32-Bit RISC Microcomputer SuperHTM RISC engine Family / SH7700 Series
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet
Section 20
Rev. 3.00 Jan. 18, 2008 Page 656 of 1458
REJ09B0033-0300
Bit
4
3
2
Bit Name
NACKF
STOP
AL/OVE
I
2
C Bus Interface (IIC)
Initial
Value
0
0
0
R/W
R/W
R/W
R/W
Description
No Acknowledge Detection Flag
[Setting condition]
[Clearing condition]
Stop Condition Detection Flag
[Setting conditions]
[Clearing condition]
Arbitration Lost Flag/Overrun Error Flag
This flag indicates that arbitration was lost in master
mode with the I
When two or more master devices attempt to seize the
bus at nearly the same time, if the I
detects data differing from the data it sent, it sets AL to 1
to indicate that the bus has been taken by another
master.
[Setting conditions]
[Clearing condition]
When no acknowledge is detected from the receive
device in transmission while the ACKE bit in ICIER is
1
When 0 is written in NACKF after reading NACKF = 1
In master mode: when a stop condition is detected
after frame transfer is completed
In slave mode: when a stop condition is detected after
the address set in SAR matches the salve address
that comes as the first byte after the detection of a
start condition
When 0 is written in STOP after reading STOP = 1
If the internal SDA and SDA pin disagree at the rise of
SCL in master transmit mode
When the SDA pin outputs high in master mode while
a start condition is detected
When 0 is written in AL/OVE after reading AL/OVE =
1
2
C bus format.
2
C bus interface

Related parts for HD6417320