DEMO9S12XEP100 Freescale Semiconductor, DEMO9S12XEP100 Datasheet - Page 616

BOARD DEMO FOR MC9S12XEP100

DEMO9S12XEP100

Manufacturer Part Number
DEMO9S12XEP100
Description
BOARD DEMO FOR MC9S12XEP100
Manufacturer
Freescale Semiconductor
Type
MCUr
Datasheet

Specifications of DEMO9S12XEP100

Contents
Board, Cables, CD
Processor To Be Evaluated
MC9S12XEP100
Data Bus Width
16 bit
Interface Type
RS-232
Silicon Manufacturer
Freescale
Core Architecture
S12
Core Sub-architecture
S12
Silicon Core Number
MC9S12
Silicon Family Name
S12XE
Rohs Compliant
Yes
For Use With/related Products
MC9S12XEP100
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DEMO9S12XEP100
Manufacturer:
PANASONIC
Quantity:
46 000
Part Number:
DEMO9S12XEP100
Manufacturer:
Freescale Semiconductor
Quantity:
135
Chapter 16 Freescale’s Scalable Controller Area Network (S12MSCANV3)
1. Read: Anytime
616
Module Base + 0x0001
Write: Anytime in initialization mode (INITRQ = 1 and INITAK = 1); CANE is write once
CLKSRC
LOOPB
LISTEN
WUPM
BORM
CANE
Field
7
6
5
4
3
2
Reset:
W
R
MSCAN Enable
0 MSCAN module is disabled
1 MSCAN module is enabled
MSCAN Clock Source — This bit defines the clock source for the MSCAN module (only for systems with a clock
generation module;
0 MSCAN clock source is the oscillator clock
1 MSCAN clock source is the bus clock
Loopback Self Test Mode — When this bit is set, the MSCAN performs an internal loopback which can be used
for self test operation. The bit stream output of the transmitter is fed back to the receiver internally. The RXCAN
input is ignored and the TXCAN output goes to the recessive state (logic 1). The MSCAN behaves as it does
normally when transmitting and treats its own transmitted message as a message received from a remote node.
In this state, the MSCAN ignores the bit sent during the ACK slot in the CAN frame acknowledge field to ensure
proper reception of its own message. Both transmit and receive interrupts are generated.
0 Loopback self test disabled
1 Loopback self test enabled
Listen Only Mode — This bit configures the MSCAN as a CAN bus monitor. When LISTEN is set, all valid CAN
messages with matching ID are received, but no acknowledgement or error frames are sent out (see
Section 16.4.4.4, “Listen-Only
applications which require “hot plugging” or throughput analysis. The MSCAN is unable to transmit any
messages when listen only mode is active.
0 Normal operation
1 Listen only mode activated
Bus-Off Recovery Mode — This bit configures the bus-off state recovery mode of the MSCAN. Refer to
Section 16.5.2, “Bus-Off
0 Automatic bus-off recovery (see Bosch CAN 2.0A/B protocol specification)
1 Bus-off recovery upon user request
Wake-Up Mode — If WUPE in CANCTL0 is enabled, this bit defines whether the integrated low-pass filter is
applied to protect the MSCAN from spurious wake-up (see
0 MSCAN wakes up on any dominant level on the CAN bus
1 MSCAN wakes up only in case of a dominant pulse on the CAN bus that has a length of T
CANE
0
7
= Unimplemented
CLKSRC
Figure 16-5. MSCAN Control Register 1 (CANCTL1)
Table 16-4. CANCTL1 Register Field Descriptions
6
0
Section 16.4.3.2, “Clock
MC9S12XE-Family Reference Manual , Rev. 1.23
Recovery,” for details.
LOOPB
Mode”). In addition, the error counters are frozen. Listen only mode supports
0
5
LISTEN
System,” and
4
1
Description
Section Figure 16-43., “MSCAN Clocking
BORM
Section 16.4.5.5, “MSCAN Sleep
0
3
WUPM
2
0
Access: User read/write
Freescale Semiconductor
SLPAK
0
1
wup
Mode”).
Scheme,”).
INITAK
0
1
(1)

Related parts for DEMO9S12XEP100