DEMO9S12XEP100 Freescale Semiconductor, DEMO9S12XEP100 Datasheet - Page 931

BOARD DEMO FOR MC9S12XEP100

DEMO9S12XEP100

Manufacturer Part Number
DEMO9S12XEP100
Description
BOARD DEMO FOR MC9S12XEP100
Manufacturer
Freescale Semiconductor
Type
MCUr
Datasheet

Specifications of DEMO9S12XEP100

Contents
Board, Cables, CD
Processor To Be Evaluated
MC9S12XEP100
Data Bus Width
16 bit
Interface Type
RS-232
Silicon Manufacturer
Freescale
Core Architecture
S12
Core Sub-architecture
S12
Silicon Core Number
MC9S12
Silicon Family Name
S12XE
Rohs Compliant
Yes
For Use With/related Products
MC9S12XEP100
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DEMO9S12XEP100
Manufacturer:
PANASONIC
Quantity:
46 000
Part Number:
DEMO9S12XEP100
Manufacturer:
Freescale Semiconductor
Quantity:
135
25.4.2.3
The Erase Verify P-Flash Section command will verify that a section of code in the P-Flash memory is
erased. The Erase Verify P-Flash Section command defines the starting point of the code to be verified and
the number of phrases. The section to be verified cannot cross a 128 Kbyte boundary in the P-Flash
memory space.
Upon clearing CCIF to launch the Erase Verify P-Flash Section command, the Memory Controller will
verify the selected section of Flash memory is erased. The CCIF flag will set after the Erase Verify P-Flash
Section operation has completed.
Freescale Semiconductor
FERSTAT
Register
Register
FSTAT
FSTAT
Erase Verify P-Flash Section Command
Table 25-37. Erase Verify P-Flash Section Command FCCOB Requirements
Table 25-38. Erase Verify P-Flash Section Command Error Handling
MGSTAT1
MGSTAT0
EPVIOLIF
MGSTAT1
MGSTAT0
ACCERR
ACCERR
Error Bit
Error Bit
FPVIOL
FPVIOL
Table 25-36. Erase Verify Block Command Error Handling
CCOBIX[2:0]
000
001
010
MC9S12XE-Family Reference Manual , Rev. 1.23
Set if CCOBIX[2:0] != 000 at command launch
Set if a Load Data Field command sequence is currently active
Set if an invalid global address [22:16] is supplied
None
Set if any errors have been encountered during the read
Set if any non-correctable errors have been encountered during the read
None
Set if CCOBIX[2:0] != 010 at command launch
Set if a Load Data Field command sequence is currently active
Set if command not available in current mode (see
Set if an invalid global address [22:0] is supplied
Set if a misaligned phrase address is supplied (global address [2:0] != 000)
Set if the requested section crosses a 128 Kbyte boundary
None
Set if any errors have been encountered during the read
Set if any non-correctable errors have been encountered during the read
Global address [15:0] of the first phrase to be verified
Number of phrases to be verified
0x03
FCCOB Parameters
Global address [22:16] of
Error Condition
Error Condition
Chapter 25 256 KByte Flash Module (S12XFTM256K2V1)
a P-Flash block
Table
25-30)
931