DEMO9S12XEP100 Freescale Semiconductor, DEMO9S12XEP100 Datasheet - Page 994

BOARD DEMO FOR MC9S12XEP100

DEMO9S12XEP100

Manufacturer Part Number
DEMO9S12XEP100
Description
BOARD DEMO FOR MC9S12XEP100
Manufacturer
Freescale Semiconductor
Type
MCUr
Datasheet

Specifications of DEMO9S12XEP100

Contents
Board, Cables, CD
Processor To Be Evaluated
MC9S12XEP100
Data Bus Width
16 bit
Interface Type
RS-232
Silicon Manufacturer
Freescale
Core Architecture
S12
Core Sub-architecture
S12
Silicon Core Number
MC9S12
Silicon Family Name
S12XE
Rohs Compliant
Yes
For Use With/related Products
MC9S12XEP100
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DEMO9S12XEP100
Manufacturer:
PANASONIC
Quantity:
46 000
Part Number:
DEMO9S12XEP100
Manufacturer:
Freescale Semiconductor
Quantity:
135
Chapter 26 384 KByte Flash Module (S12XFTM384K2V1)
26.4.2.4
The Read Once command provides read access to a reserved 64 byte field (8 phrases) located in the
nonvolatile information register of P-Flash block 0. The Read Once field is programmed using the
Program Once command described in
from the Flash block containing the Program Once reserved field to avoid code runaway.
Upon clearing CCIF to launch the Read Once command, a Read Once phrase is fetched and stored in the
FCCOB indexed register. The CCIF flag will set after the Read Once operation has completed. Valid
phrase index values for the Read Once command range from 0x0000 to 0x0007. During execution of the
Read Once command, any attempt to read addresses within P-Flash block 0 will return invalid data.
994
128
1. As defined by the memory map for FTM512K3.
2. As found in the memory map for FTM512K3.
FERSTAT
Register
FSTAT
Read Once Command
Table 26-38. Erase Verify P-Flash Section Command Error Handling
CCOBIX[2:0]
MGSTAT1
MGSTAT0
EPVIOLIF
ACCERR
Error Bit
FPVIOL
Table 26-39. Read Once Command FCCOB Requirements
000
001
010
011
100
101
MC9S12XE-Family Reference Manual , Rev. 1.23
Set if CCOBIX[2:0] != 010 at command launch
Set if a Load Data Field command sequence is currently active
Set if command not available in current mode (see
Set if an invalid global address [22:0] is supplied
Set if a misaligned phrase address is supplied (global address [2:0] != 000)
Set if the requested section crosses a 256 Kbyte boundary
None
Set if any errors have been encountered during the read
Set if any non-correctable errors have been encountered during the read
None
Section
Read Once phrase index (0x0000 - 0x0007)
0x04
26.4.2.7. The Read Once command must not be executed
Read Once word 0 value
Read Once word 1 value
Read Once word 2 value
Read Once word 3 value
FCCOB Parameters
Error Condition
Not Required
(1)
Table
(2)
26-30)
Freescale Semiconductor
2

Related parts for DEMO9S12XEP100