MPC8533EVTAQGA Freescale Semiconductor, MPC8533EVTAQGA Datasheet - Page 1235

no-image

MPC8533EVTAQGA

Manufacturer Part Number
MPC8533EVTAQGA
Description
MPU POWERQUICC 783-PBGA
Manufacturer
Freescale Semiconductor
Datasheets

Specifications of MPC8533EVTAQGA

Processor Type
MPC85xx PowerQUICC III 32-Bit
Speed
1.0GHz
Voltage
0.95 V ~ 1.05 V
Mounting Type
Surface Mount
Package / Case
783-BBGA, FCBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPC8533EVTAQGA
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Table 21-7
Freescale Semiconductor
21–23
24–31
7–20
Bits
0
1
2
3
4
5
6
NECEN Not equal context enable. Qualifies the matching of current context with programmed context as a watchpoint
SIDEN Source ID enable
TIDEN Target ID enable
ECEN Equal context enable. Qualifies the matching of current context with programmed context as a watchpoint
Name
STRT Start condition. Specifies the event that arms the watchpoint monitor to start looking for the programmed
AMD
TMD
EN
describes WMCR0 fields.
MPC8533E PowerQUICC III Integrated Host Processor Family Reference Manual, Rev. 1
Enable
0 Watchpoint monitor events are not flagged.
1 A watchpoint monitor event is flagged.
Address match disable. Qualifies address match as a watchpoint event criterion.
0 Address matching is used to recognize a watchpoint event.
1 Address matching does not affect watchpoint event detection.
Transaction match disable. Qualifies transaction type match (as defined in WMCR1[IFSEL] and WMTMR) as
a watchpoint event criterion.
0 A transaction type match is used to recognize watchpoint events.
1 A transaction type match does not affect watchpoint event detection.
event criterion, as written in the context registers described in
0 Current context match does not affect watchpoint event detection.
1 Watchpoint events are qualified by comparing current context with the programmed context event value.
Note: ECEN and NECEN must not be enabled in the same run. If both are set, watchpoint events are
event criterion, as written in the context registers described in
0 The failure of a current context match does not affect watchpoint event detection
1 Watchpoint events are qualified with NOT getting a current context compare with the programmed context
Note: ECEN and NECEN must not be enabled in the same run. If both are set, watchpoint events are
0 Source ID does not affect watchpoint event detection.
1 Watchpoint events are qualified by comparison with the programmed WMCR1(SID) value.
0 Target ID does not affect watchpoint event detection.
1 Watchpoint events are qualified by comparison with the programmed WMCR1(TID) value.
Reserved
event.
000 No event. Armed immediately
001 Trace buffer event is detected
010 Performance monitor signals overflow
011 TRIG_IN transitions from 0 to 1
100 TRIG_IN transitions from 1 to 0
101 Current context ID equals programmed context ID
110 Current context ID is not equal to programmed context ID
111 Reserved
Reserved
event value.
inhibited (never occur).
inhibited (never occur).
Table 21-7. WMCR0 Field Descriptions
Description
Section 21.3.3, “Context ID Registers.”
Section 21.3.3, “Context ID Registers.”
Debug Features and Watchpoint Facility