MPC8533EVTAQGA Freescale Semiconductor, MPC8533EVTAQGA Datasheet - Page 783

no-image

MPC8533EVTAQGA

Manufacturer Part Number
MPC8533EVTAQGA
Description
MPU POWERQUICC 783-PBGA
Manufacturer
Freescale Semiconductor
Datasheets

Specifications of MPC8533EVTAQGA

Processor Type
MPC85xx PowerQUICC III 32-Bit
Speed
1.0GHz
Voltage
0.95 V ~ 1.05 V
Mounting Type
Surface Mount
Package / Case
783-BBGA, FCBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPC8533EVTAQGA
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Table 15-28
15.5.3.3.4
The RQUEUE register enables each of the RxBD rings 0–7. By default, RxBD ring 0 is enabled.
Figure 15-25
Table 15-29
Freescale Semiconductor
11–15
16–31
Offset eTSEC1:0x2_4314; eTSEC3:0x2_6314
Reset
3–10
\
Bits
Bits
0–7
0
1
2
8
W
R
0
0 0 0 0 0 0 0 0
Name
Name
ICEN
ICCS Interrupt coalescing timer clock source.
ICFT
ICTT
EX0
describes the fields of the RXIC register.
describes the RQUEUE register.
describes the definition for the RQUEUE register.
MPC8533E PowerQUICC III Integrated Host Processor Family Reference Manual, Rev. 1
Receive Queue Control Register (RQUEUE)
Interrupt coalescing enable
0 Interrupt coalescing is disabled. Interrupts are raised as they are received.
1 Interrupt coalescing is enabled. If the eTSEC receive frame interrupt is enabled (IMASK[RXFEN] is set),
0 The coalescing timer advances count every 64 eTSEC Rx interface clocks (TSECn_GTX_CLK).
1 The coalescing timer advances count every 64 system clocks. This mode is recommended for FIFO
Reserved
Interrupt coalescing frame count threshold. While interrupt coalescing is enabled (RXIC[ICE] is set), this value
determines how many frames are received before raising an interrupt. The eTSEC threshold counter is reset
to ICFT following an interrupt. The value of ICFT must be greater than zero avoid unpredictable behavior.
Reserved
Interrupt coalescing timer threshold. While interrupt coalescing is enabled (RXIC[ICE] is set), this value
determines the maximum amount of time after receiving a frame before raising an interrupt. If frames have
been received but the frame count threshold has not been met, an interrupt is raised when the threshold timer
reaches zero. The threshold timer is reset to the value in this field and begins counting down upon receiving
the first frame having its RxBD[I] bit set. The threshold value is represented in units equal to 64 periods of the
clock specified by RXIC[ICCS]. ICTT must be greater than zero to avoid unpredictable behavior.
Reserved
Receive queue 0 extract enable.
0 Data transferred by DMA to this RxBD ring is not extracted to cache.
1 Data transferred by DMA to this RxBD ring undergoes extraction according to ATTR register.
an interrupt is raised when the threshold number of frames is reached (defined by RXIC[ICFT]) or when
the threshold timer expires (determined by RXIC[ICTT]).
operation.
7
EX0 EX1 EX2 EX3 EX4 EX5 EX6 EX7
1
8
0
9
10
0
Figure 15-25. RQUEUE Register Definition
Table 15-29. RQUEUE Field Descriptions
Table 15-28. RXIC Field Descriptions
11
0
12
0
13
0
14
0
15
0
Description
Description
16
0 0 0 0 0 0 0 0
23
Enhanced Three-Speed Ethernet Controllers
EN0 EN1 EN2 EN3 EN4 EN5 EN6 EN7
24
1
25
0
26
0
27
0
Access: Read/Write
28
0
29
0
30
0
15-53
31
0