- Current page: 186 of 310
- Download datasheet (3Mb)
TDAT042G5 SONET/SDH
155/622/2488 Mbits/s Data Interface
Register Descriptions
UT Registers
UT Provisioning Registers (R/W) (continued)
Table 61. Registers 0x020F, 0x0213, 0x0217, 0x021B: Channel [A—D] Receive Provisioning Register (R/W)
Reset default of register 0x020F = 0x0020.
Reset default of register 0x0213 = 0x0120.
Reset default of register 0x0217 = 0x0220.
Reset default of register 0x021B = 0x0320.
158
020F, 0213,
0217, 021B
Address
(Hex)
14—13
12—8
Bit #
(continued)
15
7
6
5
4
3
ATM_SIZE_Rx[A—D]
TRAFFIC_TYPE_Rx
POLLING_ENB_Rx
CLOCK_MODE_Rx
PARITY_Rx[A—D]
RxADDR_A[4:0]
RxADDR_B[4:0]
RxADDR_C[4:0]
RxADDR_D[4:0]
(continued)
[A—D]
[A—D]
[A—D]
Name
—
—
Polling Enable Receive Channel [A—D]. If
set to 1, receive polling mode is enabled.
Reserved. These bits must be written to their
reset default value (00).
Polling Receive Address Channel [A—D].
Receive polling address.
Reserved. This bit must be written to its reset
default value (0).
Clock Mode Receive Channel [A—D].
Defines if the RxCLK[A—D] is sourced or sunk.
If this bit = 1, the clock is sourced, and then
(1) the corresponding Tx clock is used as
RxCLK[A—D], and (2) this clock is also sent out
of the device via RxCLK[A—D].
If this bit = 0, CLOCK_MODE_Rx[A—D] is
sunk, and then RxCLK[A—D] acts as an input.
Default is sink.
Parity Receive Channel [A—D]. Defines if odd
(bit = 1) or even (bit = 0) parity is generated for
the data transmitted across the UTOPIA PHY
Rx interface. Default is odd.
ATM Packet Size Receive Channel [A—D].
Defines how many bytes are received per ATM
cell. Default is 53 bytes. Valid only when traffic
type is ATM cells.
Page 86 and page 87 give details of the func-
tion of this bit.
0 = standard 53-byte (also 54-byte and 56-byte)
ATM cell modes.
1 = 52-byte ATM cell mode (HEC omitted).
Traffic Type Receive Channel [A—D]. Config-
ures channel to receive either ATM cells or
packets.
Bit Value
0
1
Traffic Type
packets (default)
ATM cells
Function
Agere Systems Inc.
Data Sheet
Default
Reset
00000
00001
00010
00011
May 2001
00
0
0
0
1
0
0
Related parts for tdat04622