tdat04622 ETC-unknow, tdat04622 Datasheet - Page 232
tdat04622
Manufacturer Part Number
tdat04622
Description
Tdat Sonet/sdh 155/622/2488 Mbits/s Data Interfaces
Manufacturer
ETC-unknow
Datasheet
1.TDAT04622.pdf
(310 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
- Current page: 232 of 310
- Download datasheet (3Mb)
TDAT042G5 SONET/SDH
155/622/2488 Mbits/s Data Interface
Register Descriptions
PT Registers
Table 103. Registers 0x0AA6—0x0AAD, 0x0AAE, 0x0AB5, 0x0AB6—0x0ABD, 0x0ABE—0x0AC5: PT Con-
Reset default of registers 0x0AA6, 0x0AAE, 0x0AB6, 0x0ABE = 0xF200.
Reset default of registers 0x0AA7, 0x0AAF, 0x0AB7, 0x0ABF = 0x0000.
Reset default of registers 0x0AA8, 0x0AB0, 0x0AB8, 0x0AC0 = 0x0FFF.
Reset default of registers 0x0AA9, 0x0AB1, 0x0AB9, 0x0AC1 = 0x0000.
Reset default of registers 0x0AAA, 0x0AB2, 0x0ABA, 0x0AC2 = 0x0000.
Reset default of registers 0x0AAB, 0x0AB3, 0x0ABB, 0x0AC3 = 0x1AAA.
Reset default of registers 0x0AAC, 0x0AB4, 0x0ABC, 0x0AC4 = 0x3AAA.
Reset default of registers 0x0AAD, 0x0AB5, 0x0ABD, 0x0AC5 = 0x3333.
204
0AAD, 0AB5,
0ABD, 0AC5
Address
(Hex)
trol Parameters (R/W) (continued)
15—12
11—8
(continued)
Bit #
7—4
3—0
CNTDRDIP[A—D][3:0]
CNTDC2[A—D][3:0]
CNTDZ5[A—D][3:0]
CNTDF2[A—D][3:0]
(continued)
Name
Continuous N Times Detect Z5 Byte. Control
signal for detecting changes in state of the Z5
byte. Valid values are 0 to 15. A value of 0 or 1
causes the data monitor byte to be updated
every frame.
A value of n, where 2 ≤ n ≤ 15, of these four bits
means that the same value of the Z5 byte must
be detected n times consecutively to declare a
new value in the Z5 byte register.
Continuous N Times Detect F2 Byte. Control
signal for detecting changes in state of the F2
byte. Valid values are 0 to 15. A value of 0 or 1
causes the data monitor byte to be updated
every frame.
A value of n, where 2 ≤ n ≤ 15, of these four bits
means that the same value of the F2 byte must
be detected n times consecutively to declare a
new value in the F2 byte register.
Continuous N Times Detect RDI-P. Control
signal for detecting changes in state of the
G1[3:1] bits. Valid values are 0 to 15. A value of
0 or 1 causes the data monitor byte to be
updated every frame.
A value of n, where 2 ≤ n ≤ 15, of these four bits
means that the same value of the RDI-P byte
must be detected n times consecutively to
declare a new value in the RDI-P byte register.
Continuous N Times Detect C2 Byte. Control
signal for detecting changes in state of the C2
byte. Valid values are 0 to 15. A value of 0 or 1
causes the data monitor byte to be updated
every frame.
A value of n, where 2 ≤ n ≤ 15, of these four bits
means that the same value of the C2 byte must
be detected n times consecutively to declare a
new value in the C2 byte register.
Function
Agere Systems Inc.
Data Sheet
May 2001
Default
Reset
0x3
0x3
0x3
0x3
Related parts for tdat04622
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
Manufacturer:
ETC-unknow
Datasheet:
Part Number:
Description:
Manufacturer:
ETC-unknow