tdat04622 ETC-unknow, tdat04622 Datasheet - Page 7

no-image

tdat04622

Manufacturer Part Number
tdat04622
Description
Tdat Sonet/sdh 155/622/2488 Mbits/s Data Interfaces
Manufacturer
ETC-unknow
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
tdat046223BLL1
Quantity:
92
Part Number:
tdat046223BLL1
Quantity:
46
May 2001
Agere Systems Inc.
Path Terminator (PT)
PT1. Signal Degrade (SD) and Signal Fail (SF) Bit Behavior
Receive signal degrade and receive signal fail bits in the PT state registers (addresses 0x0838, 0x088A, 0x08DC,
and 0x092E, bits [1:0]) do not function as described. Until the signal degrade (SD) and signal fail (SF) thresholds
are programmed, the SD and SF bits will toggle on a frame-by-frame basis.
Workaround
Program thresholds during system software initialization.
Corrective Action
This functionality will be retained in its current state in future versions of the device. The advance data sheet will be
corrected to reflect the actual function of the registers.
PT2. Clear-After-Write Behavior of Signal Degrade Clear Bits
Signal degrade clear (bits 15—12) of the PT one-shot control parameters register (address 0x0AA4) are described
as one-shot, clear-after-write bits. Writing these bits should automatically set and then clear the bits. This one-shot
behavior is not observed.
Workaround
The bits must be set to 1 and then explicitly set to 0 to clear these signal degrade bits.
Corrective Action
This functionality will be retained in its current state in future versions of the device. The advance data sheet will be
corrected to reflect the actual function of the registers.
for Version 1 and 1A of the Device
5