DF2166VT33WV Renesas Electronics America, DF2166VT33WV Datasheet - Page 433

MCU 16BIT FLASH 3V 512K 144-TQFP

DF2166VT33WV

Manufacturer Part Number
DF2166VT33WV
Description
MCU 16BIT FLASH 3V 512K 144-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2100r
Datasheet

Specifications of DF2166VT33WV

Core Processor
H8S/2000
Core Size
16-Bit
Speed
33MHz
Connectivity
I²C, IrDA, LPC, SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
106
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
40K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
144-TQFP, 144-VQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF2166VT33WV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
DF2166VT33WV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
No
No
Read receive data in RDR, and
clear RDRF flag in SSR to 0
PER ∨ FER ∨ ORER = 1
Read RDRF flag in SSR
Clear RE bit in SCR to 0
Read ORER, PER, and
All data received?
FER flags in SSR
Figure 14.12 Sample Serial Reception Flowchart (1)
Start reception
Initialization
RDRF = 1
<End>
Yes
Yes
No
(Continued on next page)
Error processing
Yes
[1]
[2]
[4]
[5]
[3]
[1] SCI initialization:
[2] [3] Receive error processing and break
[4] SCI status check and receive data read:
[5] Serial reception continuation procedure:
Legend
∨ : Logical add (OR)
The RxD pin is automatically
designated as the receive data input
pin.
detection:
If a receive error occurs, read the
ORER, PER, and FER flags in SSR to
identify the error. After performing the
appropriate error processing, ensure
that the ORER, PER, and FER flags are
all cleared to 0. Reception cannot be
resumed if any of these flags are set to
1. In the case of a framing error, a
break can be detected by reading the
value of the input port corresponding to
the RxD pin.
Read SSR and check that RDRF = 1,
then read the receive data in RDR and
clear the RDRF flag to 0. Transition of
the RDRF flag from 0 to 1 can also be
identified by an RXI interrupt.
To continue serial reception, before the
stop bit for the current frame is
received, read the RDRF flag, read
RDR, and clear the RDRF flag to 0.
However, the RDRF flag is cleared
automatically when the DTC is initiated
by an RXI interrupt and reads data from
RDR.
Rev. 3.00, 03/04, page 391 of 830

Related parts for DF2166VT33WV