DF2166VT33WV Renesas Electronics America, DF2166VT33WV Datasheet - Page 453

MCU 16BIT FLASH 3V 512K 144-TQFP

DF2166VT33WV

Manufacturer Part Number
DF2166VT33WV
Description
MCU 16BIT FLASH 3V 512K 144-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2100r
Datasheet

Specifications of DF2166VT33WV

Core Processor
H8S/2000
Core Size
16-Bit
Speed
33MHz
Connectivity
I²C, IrDA, LPC, SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
106
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
40K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
144-TQFP, 144-VQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF2166VT33WV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
DF2166VT33WV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
the end of initialization, TE and RE should be set to 0 and 1, respectively. Transmission
completion can be verified by reading the TEND flag.
14.7.6
Data transmission in smart card interface mode (except in block transfer mode) is different from
that in normal serial communication interface mode in that an error signal is sampled and data is
re-transmitted. Figure 14.29 shows the data re-transfer operation during transmission.
1. If an error signal from the receiving end is sampled after one frame of data has been
2. For the frame in which an error signal is received, the TEND bit in SSR is not set to 1. Data is
3. If no error signal is returned from the receiving end, the ERS bit in SSR is not set to 1. In this
Figure 14.31 shows a sample flowchart for transmission. All the processing steps are
automatically performed using a TXI interrupt request to activate the DTC. In transmission, the
TEND and TDRE flags in SSR are simultaneously set to 1, thus generating a TXI interrupt request
when TIE in SCR is set. This activates the DTC by a TXI request thus allowing transfer of
transmit data if the TXI interrupt request is specified as a source of DTC activation beforehand.
The TDRE and TEND flags are automatically cleared to 0 at data transfer by the DTC. If an error
occurs, the SCI automatically re-transmits the same data. During re-transmission, TEND remains
as 0, thus not activating the DTC. Therefore, the SCI and DTC automatically transmit the
specified number of bytes, including re-transmission in the case of error occurrence. However, the
ERS flag is not automatically cleared; the ERS flag must be cleared by previously setting the RIE
bit to 1 to enable an ERI interrupt request to be generated at error occurrence.
When transmitting/receiving data using the DTC, be sure to set and enable it prior to making SCI
settings. For DTC settings, see section 7, Data Transfer Controller (DTC).
transmitted, the ERS bit in SSR is set to 1. Here, an ERI interrupt request is generated if the
RIE bit in SCR is set to 1. Clear the ERS bit to 0 before the next parity bit is sampled.
re-transferred from TDR to TSR allowing automatic data retransmission.
case, one frame of data is determined to have been transmitted including re-transfer, and the
TEND bit in SSR is set to 1. Here, a TXI interrupt request is generated if the TIE bit in SCR is
set to 1. Writing transmit data to TDR starts transmission of the next data.
Serial Data Transmission (Except in Block Transfer Mode)
Rev. 3.00, 03/04, page 411 of 830