ATMEGA128RFA1-ZU Atmel, ATMEGA128RFA1-ZU Datasheet - Page 123

IC AVR MCU 2.4GHZ XCEIVER 64QFN

ATMEGA128RFA1-ZU

Manufacturer Part Number
ATMEGA128RFA1-ZU
Description
IC AVR MCU 2.4GHZ XCEIVER 64QFN
Manufacturer
Atmel
Series
ATMEGAr

Specifications of ATMEGA128RFA1-ZU

Frequency
2.4GHz
Data Rate - Maximum
2Mbps
Modulation Or Protocol
802.15.4 Zigbee
Applications
General Purpose
Power - Output
3.5dBm
Sensitivity
-100dBm
Voltage - Supply
1.8 V ~ 3.6 V
Current - Receiving
12.5mA
Current - Transmitting
14.5mA
Data Interface
PCB, Surface Mount
Memory Size
128kB Flash, 4kB EEPROM, 16kB RAM
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Package / Case
64-VFQFN, Exposed Pad
Rf Ic Case Style
QFN
No. Of Pins
64
Supply Voltage Range
1.8V To 3.6V
Operating Temperature Range
-40°C To +85°C
Svhc
No SVHC (15-Dec-2010)
Rohs Compliant
Yes
Processor Series
ATMEGA128x
Core
AVR8
Data Bus Width
8 bit
Program Memory Type
Flash
Program Memory Size
128 KB
Data Ram Size
16 KB
Interface Type
JTAG
Maximum Clock Frequency
16 MHz
Number Of Programmable I/os
38
Number Of Timers
6
Operating Supply Voltage
1.8 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
EWAVR, EWAVR-BL
Development Tools By Supplier
ATAVR128RFA1-EK1
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATMEGA128RFA1-ZU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATMEGA128RFA1-ZUR
Manufacturer:
ON
Quantity:
56 000
9.12.27 PLL_DCU – Transceiver Delay Cell Calibration Control Register
9.12.28 PART_NUM – Device Identification Register (Part Number)
8266B-MCU Wireless-03/11
This register controls the operation of the center frequency calibration loop.
• Bit 7 – PLL_CF_START - Start Center Frequency Calibration
PLL_CF_START = 1 initiates the center frequency calibration. The calibration cycle has
finished after 35 µs (typical). The register bit is cleared immediately after finishing the
calibration.
• Bit 6:0 – Resx6:0 - Reserved
This register controls the operation of the calibration loop of the delay cell.
• Bit 7 – PLL_DCU_START - Start Delay Cell Calibration
PLL_DCU_START = 1 initiates the delay cell calibration. The calibration cycle has
finished after at most 6 µs. The register bit is cleared immediately after finishing the
calibration.
• Bit 6:0 – Resx6:0 - Reserved
This register contains the part number of the device.
• Bit 7:0 – PART_NUM7:0 - Part Number
These bits decode the part number of the device according to the following table.
Bit
NA ($15A)
Read/Write
Initial Value
Bit
NA ($15A)
Read/Write
Initial Value
Bit
NA ($15B)
Read/Write
Initial Value
Bit
NA ($15B)
Read/Write
Initial Value
Bit
NA ($15C)
Read/Write
Initial Value
PLL_DCU_START
R
7
1
Resx3
RW
RW
3
0
7
0
R
6
0
Resx3
Resx1
RW
RW
3
0
1
1
R
5
0
Resx2
Resx6
RW
2
0
R
6
0
PART_NUM7:0
R
4
0
R
3
0
Resx1
Resx5
RW
RW
1
0
5
1
R
2
0
Resx2
Resx0
ATmega128RFA1
RW
RW
2
1
0
1
R
1
1
Resx0
Resx4
RW
RW
0
0
4
0
R
0
1
PART_NUM
PLL_DCU
PLL_CF
PLL_CF
PLL_DCU
123