ATMEGA128RFA1-ZU Atmel, ATMEGA128RFA1-ZU Datasheet - Page 72

IC AVR MCU 2.4GHZ XCEIVER 64QFN

ATMEGA128RFA1-ZU

Manufacturer Part Number
ATMEGA128RFA1-ZU
Description
IC AVR MCU 2.4GHZ XCEIVER 64QFN
Manufacturer
Atmel
Series
ATMEGAr

Specifications of ATMEGA128RFA1-ZU

Frequency
2.4GHz
Data Rate - Maximum
2Mbps
Modulation Or Protocol
802.15.4 Zigbee
Applications
General Purpose
Power - Output
3.5dBm
Sensitivity
-100dBm
Voltage - Supply
1.8 V ~ 3.6 V
Current - Receiving
12.5mA
Current - Transmitting
14.5mA
Data Interface
PCB, Surface Mount
Memory Size
128kB Flash, 4kB EEPROM, 16kB RAM
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Package / Case
64-VFQFN, Exposed Pad
Rf Ic Case Style
QFN
No. Of Pins
64
Supply Voltage Range
1.8V To 3.6V
Operating Temperature Range
-40°C To +85°C
Svhc
No SVHC (15-Dec-2010)
Rohs Compliant
Yes
Processor Series
ATMEGA128x
Core
AVR8
Data Bus Width
8 bit
Program Memory Type
Flash
Program Memory Size
128 KB
Data Ram Size
16 KB
Interface Type
JTAG
Maximum Clock Frequency
16 MHz
Number Of Programmable I/os
38
Number Of Timers
6
Operating Supply Voltage
1.8 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
EWAVR, EWAVR-BL
Development Tools By Supplier
ATAVR128RFA1-EK1
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATMEGA128RFA1-ZU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATMEGA128RFA1-ZUR
Manufacturer:
ON
Quantity:
56 000
9.5.5.5 Measurement Time
9.5.6 Link Quality Indication (LQI)
9.5.6.1 Overview
72
ATmega128RFA1
The response time for a manually initiated CCA measurement depends on the receiver
state.
In RX_ON state the CCA measurement is done over eight symbol periods and the
result is accessible 140 µs after the request (see section
Request" on
In BUSY_RX state the CCA measurement duration depends on the CCA Mode and the
CCA request relative to the reception of an SHR. The end of the CCA measurement is
indicated by a TRX24_CCA_ED_DONE interrupt. The variation of a CCA measurement
period in BUSY_RX state is described in
Table 9-22. CCA Measurement Period and Access in BUSY_RX state
It is recommended to perform CCA measurements in RX_ON state only. To avoid
accidental switching to BUSY_RX state the SHR detection can be disabled by setting
bit RX_PDT_DIS of register RX_SYN. Refer to section
details. The receiver remains in RX_ON state to perform a CCA measurement until the
register bit RX_PDT_DIS is set back to continue the frame reception. In this case the
CCA measurement duration is 8 symbol periods.
According to IEEE 802.15.4 the LQI measurement is a characterization of the strength
and/or quality of a received packet. The measurement may be implemented using
receiver ED, a signal-to-noise ratio estimation or a combination of these methods. The
use of the LQI result by the network or application layers is not specified in this
standard. LQI values shall be an integer ranging from 0x00 to 0xFF. The minimum and
maximum LQI values (0x00 and 0xFF) should be associated with the lowest and
highest quality compliant signals, respectively, and LQI values in between should be
uniformly distributed between these two limits.
The LQI measurement of the radio transceiver is implemented as a measure of the link
quality which can be described with the packet error rate (PER) of this link. A LQI value
CCA Mode
Note:
1
2
3
0
1. After receiving the SHR an automated ED measurement is started with a length of
8 symbol periods (PSDU rate 250 kb/s), refer to section
on
for the CCA measurement. Only one automated ED measurement per frame is
performed.
page 71).
Request within ED measurement
Energy above threshold.
CCA result is available after finishing
automated ED measurement period.
Carrier sense only.
CCA result is immediately available after request.
Carrier sense with Energy above threshold (AND).
CCA result is available after finishing
automated ED measurement period.
Carrier sense with Energy above threshold (OR).
CCA result is available after finishing
automated ED measurement period.
page 68. This automated ED measurement must be finished to provide a result
Table 9-22
(1)
below.
Request after ED measurement
CCA result is immediately available
after request.
CCA result is immediately available
after request.
CCA result is immediately available
after request.
"Receiver (RX)" on page 74
"Configuration and CCA
"Energy Detection (ED)"
8266A-MCU Wireless-12/09
for

Related parts for ATMEGA128RFA1-ZU