HD64F2638F20J Renesas Electronics America, HD64F2638F20J Datasheet - Page 551

IC H8S MCU FLASH 256K 128-QFP

HD64F2638F20J

Manufacturer Part Number
HD64F2638F20J
Description
IC H8S MCU FLASH 256K 128-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2600r
Datasheets

Specifications of HD64F2638F20J

Core Processor
H8S/2600
Core Size
16-Bit
Speed
20MHz
Connectivity
CAN, SCI, SmartCard
Peripherals
Motor Control PWM, POR, PWM, WDT
Number Of I /o
72
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 12x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
128-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F2638F20J
Manufacturer:
PENESAS
Quantity:
252
H8S/2639, H8S/2638, H8S/2636,
H8S/2630, H8S/2635 Group
In serial reception, the SCI operates as described below.
[1] The SCI performs internal initialization in synchronization with serial clock input or output.
[2] The received data is stored in RSR in LSB-to-MSB order.
[3] If the RIE bit in SCR is set to 1 when the RDRF flag changes to 1, a receive data full interrupt
• Simultaneous serial data transmission and reception (clocked synchronous mode)
REJ09B0103-0800 Rev. 8.00
May 28, 2010
Serial
clock
Serial
data
RDRF
ORER
After reception, the SCI checks whether the RDRF flag is 0 and the receive data can be
transferred from RSR to RDR.
If this check is passed, the RDRF flag is set to 1, and the receive data is stored in RDR. If a
receive error is detected in the error check, the operation is as shown in table 13-11.
Neither transmit nor receive operations can be performed subsequently when a receive error
has been found in the error check.
(RXI) request is generated.
Also, if the RIE bit in SCR is set to 1 when the ORER flag changes to 1, a receive error
interrupt (ERI) request is generated.
Figure 13-19 shows an example of SCI operation in reception.
Figure 13-20 shows a sample flowchart for simultaneous serial transmit and receive
operations.
The following procedure should be used for simultaneous serial data transmit and receive
operations.
RXI interrupt request
generated
Figure 13-19 Example of SCI Operation in Reception
Bit 7
RDR data read and
RDRF flag cleared to 0
in RXI interrupt service
routine
Bit 0
1 frame
Bit 7
Bit 0
RXI interrupt request
generated
Section 13 Serial Communication Interface (SCI)
Bit 1
ERI interrupt request
generated by overrun
error
Bit 6
Page 501 of 1458
Bit 7

Related parts for HD64F2638F20J