SAM4S16C Atmel Corporation, SAM4S16C Datasheet - Page 1005

no-image

SAM4S16C

Manufacturer Part Number
SAM4S16C
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM4S16C

Flash (kbytes)
1024 Kbytes
Pin Count
100
# Of Touch Channels
32
Hardware Qtouch Acquisition
No
Max I/o Pins
79
Ext Interrupts
79
Usb Transceiver
1
Quadrature Decoder Channels
2
Usb Speed
Full Speed
Usb Interface
Device
Spi
3
Twi (i2c)
2
Uart
4
Ssc
1
Sd / Emmc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
16
Adc Resolution (bits)
12
Adc Speed (ksps)
1000
Analog Comparators
1
Resistive Touch Screen
No
Dac Channels
2
Dac Resolution (bits)
12
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
128
Self Program Memory
YES
External Bus Interface
1
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
6
Output Compare Channels
6
Input Capture Channels
6
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
through the UDP_FDRx register. Once a transfer is done, the device firmware must release Bank 0 to the USB peripheral
device by clearing RX_DATA_BK0.
After setting or clearing this bit, a wait time of 3 UDPCK clock cycles and 3 peripheral clock cycles is required before
accessing DPR.
• RXSETUP: Received Setup
This flag generates an interrupt while it is set to one.
Read:
0 = No setup packet available.
1 = A setup data packet has been sent by the host and is available in the FIFO.
Write:
0 = Device firmware notifies the USB peripheral device that it has read the setup data in the FIFO.
1 = No effect.
This flag is used to notify the USB device firmware that a valid Setup data packet has been sent by the host and success-
fully received by the USB device. The USB device firmware may transfer Setup data from the FIFO by reading the
UDP_FDRx register to the microcontroller memory. Once a transfer has been done, RXSETUP must be cleared by the
device firmware.
Ensuing Data OUT transaction is not accepted while RXSETUP is set.
• STALLSENT: Stall Sent (Control, Bulk Interrupt Endpoints)/ISOERROR (Isochronous Endpoints)
This flag generates an interrupt while it is set to one.
STALLSENT: This ends a STALL handshake.
Read:
0 = The host has not acknowledged a STALL.
1 = Host has acknowledged the stall.
Write:
0 = Resets the STALLSENT flag, clears the interrupt.
1 = No effect.
This is mandatory for the device firmware to clear this flag. Otherwise the interrupt remains.
Refer to chapters 8.4.5 and 9.4.5 of the Universal Serial Bus Specification, Rev. 2.0 for more information on the STALL
handshake.
ISOERROR: A CRC error has been detected in an isochronous transfer.
Read:
0 = No error in the previous isochronous transfer.
1 = CRC error has been detected, data available in the FIFO are corrupted.
Write:
0 = Resets the ISOERROR flag, clears the interrupt.
1 = No effect.
11100A–ATARM–28-Oct-11
11100A–ATARM–28-Oct-11
SAM4S
SAM4S
1005