SAM4S16C Atmel Corporation, SAM4S16C Datasheet - Page 911

no-image

SAM4S16C

Manufacturer Part Number
SAM4S16C
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM4S16C

Flash (kbytes)
1024 Kbytes
Pin Count
100
# Of Touch Channels
32
Hardware Qtouch Acquisition
No
Max I/o Pins
79
Ext Interrupts
79
Usb Transceiver
1
Quadrature Decoder Channels
2
Usb Speed
Full Speed
Usb Interface
Device
Spi
3
Twi (i2c)
2
Uart
4
Ssc
1
Sd / Emmc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
16
Adc Resolution (bits)
12
Adc Speed (ksps)
1000
Analog Comparators
1
Resistive Touch Screen
No
Dac Channels
2
Dac Resolution (bits)
12
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
128
Self Program Memory
YES
External Bus Interface
1
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
6
Output Compare Channels
6
Input Capture Channels
6
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
Table 36-5.
11100A–ATARM–28-Oct-11
11100A–ATARM–28-Oct-11
Dead-Time Values
(
Duty-Cycle Values
(
Update Period Value
(
PWM_DTUPDx)
PWM_CDTYUPDx)
PWM_SCUPUPD)
Method 1: Manual write of duty-cycle values and manual trigger of the update
Summary of the Update of Registers of Synchronous Channels (Continued)
In this mode, the update of the period value, the duty-cycle values and the dead-time values
must be done by writing in their respective update registers with the CPU (respectively
PWM_CPRDUPDx, PWM_CDTYUPDx and PWM_DTUPDx).
To trigger the update, the user must use the bit UPDULOCK of the
Update Control Register”
PWM period) the synchronous channels:
After writing the UPDULOCK bit to 1, it is held at this value until the update occurs, then it is read
0.
Sequence for Method 1:
PWM period as soon as the bit
Update is triggered at the next
• If the bit UPDULOCK is set to 1, the update is done at the next PWM period of the
• If the UPDULOCK bit is not set to 1, the update is locked and cannot be performed.
1. Select the manual write of duty-cycle values and the manual update by setting the
2. Define the synchronous channels by the SYNCx bits in the PWM_SCM register.
3. Enable the synchronous channels by writing CHID0 in the PWM_ENA register.
4. If an update of the period value and/or the duty-cycle values and/or the dead-time val-
5. Set UPDULOCK to 1 in PWM_SCUC.
6. The update of the registers will occur at the beginning of the next PWM period. At this
synchronous channels.
UPDULOCK is set to 1
UPDM field to 0 in the PWM_SCM register
ues is required, write registers that need to be updated (PWM_CPRDUPDx,
PWM_CDTYUPDx and PWM_DTUPDx).
moment the UPDULOCK bit is reset, go to
Write by the CPU
Not applicable
Not applicable
UPDM=0
(PWM_SCUC) which allows to update synchronously (at the same
the bit UPDULOCK is set to 1
next PWM period as soon as
Update is triggered at the
Write by the CPU
Write by the CPU
UPDM=1
PWM period as soon as the update period
PWM period as soon as the update period
counter has reached the value UPR
counter has reached the value UPR
Step
Update is triggered at the next
Update is triggered at the next
4.) for new values.
Write by the CPU
Write by the PDC
“PWM Sync Channels
UPDM=2
SAM4S
SAM4S
911
911