TMPM382FSFG Toshiba, TMPM382FSFG Datasheet - Page 492

no-image

TMPM382FSFG

Manufacturer Part Number
TMPM382FSFG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMPM382FSFG

Product Summaries
Summary
Lead Free
Yes
Rohs Compatible Product(s)
Available
Rom (kbytes)
64K
Rom Type
Flash
Ram (kbytes)
8K
Number Of Pins
64
Package
QFP(14x14)
Vcc
5V
Cpu Mhz
40
Ssp (ch) Spi
1
I2c/sio (ch)
1
Uart/sio (ch)
3
Usb
-
Can
-
Ethernet
-
External Bus Interface
N
Cs/wait Controller (ch)
-
Dma Controller
2
10-bit Da Converter
-
10-bit Ad Converter
-
12-bit Ad Converter
10
16-bit Timer / Counter
6
Motor / Igbt Control
Y
Real Time Clock
1
Watchdog Timer
Y
Osc Freq Detect
Y
Clock Gear
Y
Low-power Hold Function
-
Remote Control Interface
Y
Hardware Cec Controller
-
Comparators
-
Low-voltage Detector
Y
Etm Hardware Trace
2-bit
16 Remote control signal preprocessor (RMC)
16.3.1.7
16.3.1.8
RMCRCR2 <RMCLD>, RMC starts receiving data if it recognizes a signal of which low width is shorter
than a maximum low width of leader detection specified in the RMCRCR1 <RMCLLMAX7:0> bits.
RMC keeps receiving data until the final data bit is received.
data bit determination of 0 or 1 are applied regardless of whether a signal has a leader or not. Thus
receivable remote control signals are limited.
RMCRCR2 register <RMCLD>=1
RMC stops reception by clearing the RMCREN <RMCREN> bit to “0” (reception disabled).
Clearing this bit during reception stops reception immediately and the received data is discarded.
Setting RMCRCR2 <RMCLD> enables RMC to receive signals with or without a leader. By setting
If RMCRCR2 <RMCLD> is enabled, the same settings of error detection, reception completion and
Stopping Reception
Receiving Remote Control Signal without Leader
Waiting
leader
for
TMPM380/M382 - 22 / 25 -
Leader waveform
Maximum data bit cycle < RMCDMAX7:0>
Maximum data bit cycle is detected if a
signal stays low shorter than specified and
longer than a maximum data bit cycle.
Minimum low width <RMCLLMIN7:0>
A waveform of which low width is
shorter than specified is
determined as the beginning of
data. RMC starts data reception.
TMPM380/M382

Related parts for TMPM382FSFG