R88M-W75030T-S1 Omron, R88M-W75030T-S1 Datasheet - Page 176

no-image

R88M-W75030T-S1

Manufacturer Part Number
R88M-W75030T-S1
Description
SERVO MOTOR 750W 200V
Manufacturer
Omron
Datasheet

Specifications of R88M-W75030T-S1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88MW75030TS1
• Use ground lines with a minimum thickness of 3.5 mm
• If no-fuse breakers are installed at the top and the power supply line is wired from the lower duct,
• No-fuse breakers, surge absorbers, and noise filters (NF) should be positioned near the input termi-
• Wire the noise filter as shown at the left in the following illustration. The noise filter should be
• Use twisted-pair cables for the power supply cables whenever possible, or bind the cables.
• Separate power supply cables and signal cables when wiring.
When selecting no-fuse breakers, take into consideration the maximum output current and the inrush
current.
AC input
Ground
Correct: Properly twisted
3-20
System Design and Installation
Correct: Separate input and output
lines are as short as possible.
use metal tubes for wiring and make sure that there is adequate distance between the input lines
and the internal wiring. If input and output lines are wired together, noise resistance will decrease.
nal block (ground plate), and I/O lines should be isolated and wired using the shortest distance pos-
sible.
installed at the entrance to the control box whenever possible.
No-fuse Breakers (NFB)
Selecting Components
This section explains the criteria for selecting the connection components required for
improving noise resistance. These criteria include capacity performance, applicable
range, and so on. For more details, contact the manufacturers directly.
1
2
3
NF
E
4
5
6
L1C
L2C
Driver
AC output
WRONG: Noise not filtered effectively
AC input
Ground
AC output
Correct: Cables are bound.
Binding
2
, and arrange the wiring so that the ground
1
2
3
NF
E
4
5
6
L1
L2
L3
Driver
Chapter 3

Related parts for R88M-W75030T-S1