R88M-W75030T-S1 Omron, R88M-W75030T-S1 Datasheet - Page 181

no-image

R88M-W75030T-S1

Manufacturer Part Number
R88M-W75030T-S1
Description
SERVO MOTOR 750W 200V
Manufacturer
Omron
Datasheet

Specifications of R88M-W75030T-S1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88MW75030TS1
System Design and Installation
• Use twisted-pair cables for the power supply cables whenever possible, or bind the cables.
• Separate power supply cables and signal cables when wiring.
• Construct the control box case of metal, and weld the joints between the top, bottom, and sides so
• For assembly, strip the paint off of joined areas (or mask them during painting), to make them elec-
• If gaps are opened in the control box case when tightening down screws, make adjustments to pre-
• Do not leave any conducting part unconnected.
• Connect to the case all Units inside of the case.
• Construct the door of metal.
• Use a water draining structure where the door and case fit together, and leave no gaps. (Refer to
• Use conductive packing between the door and the case, as shown in the diagrams below. Strip the
AC input
Ground
Correct: Properly twisted
Correct: Separate input and output
that they will be electrically conductive.
trically conductive.
vent this from occurring.
the diagrams below.)
paint off of the sections of the door and case that will be in contact with the conductive packing (or
mask them during painting), so that they will be electrically conductive.
Case Structure
Door Structure
Control Box Structure
If there are gaps in the control box from cable openings, operating panel installation
holes, gaps around the door, and so on, it may allow electric waves to penetrate. In
order to prevent this from occurring, take the measures described below.
1
2
3
NF
E
4
5
6
L1C
L2C
Driver
AC output
WRONG: Noise not filtered effectively
AC input
Ground
AC output
Correct: Cables are bound.
Binding
1
2
3
NF
E
4
5
6
L1
L2
L3
Driver
Chapter 3
3-25

Related parts for R88M-W75030T-S1