R88M-W75030T-S1 Omron, R88M-W75030T-S1 Datasheet - Page 370

no-image

R88M-W75030T-S1

Manufacturer Part Number
R88M-W75030T-S1
Description
SERVO MOTOR 750W 200V
Manufacturer
Omron
Datasheet

Specifications of R88M-W75030T-S1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88MW75030TS1
5-38
Troubleshooting
DB (dynamic
brake) does not
operate.
The Servomotor is
making strange
noises.
Symptom
The parameter setting is
incorrect.
DB resistance is discon-
nected.
DB drive circuit is defec-
tive.
The mechanical installation
is faulty.
There is a problem with the
bearings.
The source of vibration is
in another machine.
Noise is carried because
the input signal line specifi-
cations are incorrect.
Noise is carried because
the encoder cable specifi-
cations are incorrect.
The encoder cable is car-
rying noise because the
distance exceeds the oper-
ating range.
Noise interference is
occurring because of dam-
age to the encoder cable.
There is excessive noise
interference to the encoder
cable.
The electric potential of the
FG is fluctuating due to
influence from machinery
(such as welders) in the
vicinity of the Servomotor.
The Servo Driver pulse
count is incorrect due to
noise.
Probable cause
• Check the setting for
• Is there excessive inertia,
• A DB circuit component is
• Are Servomotor mounting
• Are couplings off center?
• Are couplings unbalanced? • Balance the couplings.
• Check for sounds and
• Have any foreign objects
• Is twisted-pair wire or
• Is twisted-pair wire or
• Use a maximum wiring dis-
• The encoder cable is
• Is the encoder cable bun-
• What is the grounding sta-
• Is noise being carried to the
Pn001.0.
rotation speed, or fre-
quency of DB use?
defective.
screws loose?
vibration around the bear-
ings.
gotten into the movable
parts of the machine, or is
there any damage or defor-
mation?
twisted-pair bound shielded
core wire of 0.12 mm
made of tin-coated soft
copper, being used?
twisted-pair bound shielded
core wire of 0.12 mm
made of tin-coated soft
copper, being used?
tance of 20 m.
crimped, or deterioration of
the insulation is allowing
noise to affect the signal
line.
dled with, or close to, lines
carrying a large current?
tus of equipment such as
welding machines near the
Servomotor (e.g., imper-
fectly grounded, not
grounded at all)?
line for signals coming from
the encoder?
Items to check
2
2
min.,
min.,
• Correct the parameter set-
• Replace the Servo Driver
• Replace the Servo Driver.
• Tighten the mounting
• Center the couplings.
• If there are any abnormali-
• Consult with the maker of
• Make sure that input signal
• Make sure that the encoder
• Make sure that the encoder
• Correct the cable installa-
• Arrange the cable so that
• Ground the machinery to
• Implement measures
ting.
and check the load system.
screws.
ties, please contact an
OMRON representative.
the machine.
lines conform to the specifi-
cations.
cable conforms to the spec-
ifications.
cable distance conforms to
the specifications.
tion.
the encoder cable is not
affected by surges.
prevent branching to the
encoder's FG.
against noise in the
encoder wiring.
Countermeasures
Chapter 5

Related parts for R88M-W75030T-S1