Operation
4-8-2 Status Display Mode
• The Status Display Mode indicates the internal status of the driver using bit display (LED ON/OFF),
• Status Display Mode is the mode in which the Servo Driver starts when the power supply is first
Status Display Mode
Rotation detected
Detection during command input
Servomotor rotation detection
Servo ON/OFF
Command input detection
CONNECT
a.@@@
and symbol display (7-segment LEDs).
turned ON.
Bit Data Display Contents
Symbol Display Contents
CONNECT
Bit data
Bit data
Servo ON/OFF
Normal: Bit display
Error: Symbol display (Example: A.020)
Status
display
Lit during Servomotor rotation.
Lit when Servo is OFF. Not lit while Servo is ON.
Lit during command input.
Lit when MECHATROLINK-II communications begin.
Alarm display (Refer to alarm table.)
Not lit
Not lit
Not lit
Contents
Contents
Not lit
Chapter 4