R88M-W75030T-S1 Omron, R88M-W75030T-S1 Datasheet - Page 193

no-image

R88M-W75030T-S1

Manufacturer Part Number
R88M-W75030T-S1
Description
SERVO MOTOR 750W 200V
Manufacturer
Omron
Datasheet

Specifications of R88M-W75030T-S1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88MW75030TS1
System Design and Installation
Connect an External Regeneration Resistor between the B1 and B2 terminals.
Note When using the R88A-RR22047S, connect the thermal switch output so that the power supply
Remove the short-circuit wiring between B2 and B3, and then connect an External Regeneration
Resistor between the B1 and B2 terminals.
Note 1. The short-circuit wiring between B2 and B3 must be removed.
Note 2. When using the R88A-RR22047S, connect the thermal switch output so that the power sup-
R88D-WNA5L-ML2 to WN01L-ML2
R88D-WN02L-ML2 to WN04L-ML2
R88D-WNA5H-ML2 to WN01H-ML2
R88D-WN02H-ML2 to WN04H-ML2
R88D-WN05H-ML2 to WN10H-ML2
R88D-WN15H-ML2
R88D-WN20H-ML2 to WN30H-ML2
Servo Driver
Servo Driver
R88D-WNA5L-ML2/01L-ML2/02L-ML2/04L-ML2/A5H-ML2/01H-ML2/02H-ML2/
04H-ML2
R88D-WN05H-ML2/08H-ML2/10H-ML2/20H-ML2/30H-ML2
Servo Driver Minimum Connection Resistance and External
Regeneration Resistor Combinations
Wiring External Regeneration Resistance
will be shut off when open.
ply will be shut off when open.
Servo Driver
B1/
B1/
B2
B2
B3
External Regeneration Resistor
External Regeneration Resistor
← Remove
40
40
40
40
40
20
12
Minimum Connection
Resistance ( Ω )
1
1, 2
1
1, 2
1, 2, 3
1, 2, 3, 4, 5
1, 2, 3, 4, 5, 6
Resistor Combinations
External Regeneration
Chapter 3
3-37

Related parts for R88M-W75030T-S1