Operation
• This parameter sets the switching speed for the step 1 and step 2 deceleration when two-step
• Sets the bias for when an exponential filter is used for the position command filter.
• This parameter sets the time constant for when an exponential filter is used for the position com-
• Sets the average movement time for when and an average movement filter is used for the position
• If the Servo Driver is used with the CJ1W-MCH71 or CS1W-MCH71, this parameter will be set to
Note Do not change setting.
• Sets the distance from the external signal input position when external positioning is executed. For
Pn80F
Setting
range
Pn810
Setting
range
Pn811
Setting
range
Pn812
Setting
range
Pn813
Setting
range
Pn814
Setting
range
Pn816.0
Setting
range
deceleration is executed. When using one-step acceleration, set the deceleration parameter switch-
ing speed (Pn80F) to 0.
mand filter.
command filter. Set when using S-curve acceleration/deceleration.
0032.
If parameters are edited with the WMON-ML2 connected, this parameter will set to 0000.
If this happens, you must reset this parameter to 0032 from the CJ1W-MCH71 or CS1W-MCH71.
a negative direction or if the distance is short, operation is reversed after decelerating to a stop.
Origin Search Parameters (Pn816 to Pn819)
Deceleration parameter switching speed (Position)
0 to 65535
Exponential acceleration/deceleration bias (Position)
0 to 32767
Exponential acceleration/deceleration time constant (Position)
0 to 5100
Moving average time (Position)
0 to 5100
Not used.
---
Final travel distance for external positioning (Position)
− 1073741823
to
1073741823
Zero point return mode settings -- Zero point return direction (Position)
0, 1
Unit
Unit
Unit
Unit
Unit
Unit
Unit
× 100 Com-
mand unit/s
Command
unit/s
× 0.1 ms
× 0.1 ms
---
Command
unit
---
Default
setting
Default
setting
Default
setting
Default
setting
Default
setting
Default
setting
Default
setting
0
0
0
0
0
100
0
Restart
power?
Restart
power?
Restart
power?
Restart
power?
Restart
power?
Restart
power?
Restart
power?
Chapter 4
No
No
No
No
No
No
No
4-71