Troubleshooting
5-5
Maintenance and Inspection Precautions
The periodic maintenance cycle depends on the installation environment and application conditions
of the Servomotor or Driver. Recommended maintenance times are listed below for Servomotors and
Drivers. Use these for reference in determining actual maintenance schedules.
• Recommended Periodic Maintenance
• The radial loads during operation (rotation) on timing pulleys and other components contacting
• Recommended Periodic Maintenance
!WARNING
!Caution
Application Conditions: Ambient Servomotor operating temperature of 40 ° C, within allowable shaft
belts is twice the still load. Consult with the belt and pulley manufacturers and adjust designs and
system settings so that the allowable shaft load is not exceeded even during operation. If a Servo-
motor is used under a shaft load exceeding the allowable limit, the Servomotor shaft can break, the
bearings can burn out, and other problems can occur.
Servomotors
Servo Drivers
Bearings:
Reduction gear: 20,000 hours
Oil seal:
Aluminum analytical capacitors: 50,000 hours, at an ambient Servo Driver operating temperature
Axle fan: 30,000 hours, at an ambient Servo Driver operating temperature of 40 ° C and an ambient
Servomotors and Servo Drivers contain many components and will operate properly
only when each of the individual components is operating properly. Some of the
electrical and mechanical components require maintenance depending on application
conditions. In order to ensure proper long-term operation of Servomotors and Drivers,
periodic inspection and part replacement is required according to the life of the
components.
Periodic Maintenance
humidity of 65%.
Do not attempt to disassemble, repair, or modify any Units. Any attempt to do so
may result in malfunction, fire, or electric shock.
Resume operation only after transferring to the new Unit the contents of the data
required for operation. Not doing so may result in an unexpected operation.
20,000 hours
5,000 hours
load, rated operation (rated torque and r/m), installed as described in oper-
ation manual.
of 40 ° C, rated operation (rated torque), installed as described in
operation manual.