R88M-W75030T-S1 Omron, R88M-W75030T-S1 Datasheet - Page 355

no-image

R88M-W75030T-S1

Manufacturer Part Number
R88M-W75030T-S1
Description
SERVO MOTOR 750W 200V
Manufacturer
Omron
Datasheet

Specifications of R88M-W75030T-S1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88MW75030TS1
Troubleshooting
a.740
Display
Inrush resistance
overload
Error
Occurs when the
control circuit
power supply is
turned ON.
Occurs at times
other than when
the main-circuit
power supply is
turned ON and
OFF.
Occurs when the
main-circuit power
supply is turned
ON and OFF.
Status when
error occurs
• The Servo Driver board is
• The Servo Driver board is
• The allowable main-cir-
• Servo Driver is defective. • Replace the Servo
defective.
defective.
cuit power supply ON/
OFF frequency was
exceeded for the inrush
current limit resistance.
Cause of error
• Replace the Servo
• Replace the Servo
• Reduce the main circuit
Driver.
Driver.
power supply ON/OFF
frequency
(to 5 times/min).
Driver.
Countermeasures
Chapter 5
5-23