R88M-W75030T-S1 Omron, R88M-W75030T-S1 Datasheet - Page 288

no-image

R88M-W75030T-S1

Manufacturer Part Number
R88M-W75030T-S1
Description
SERVO MOTOR 750W 200V
Manufacturer
Omron
Datasheet

Specifications of R88M-W75030T-S1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88MW75030TS1
The following restrictions apply during operation.
• When setting this function, set the operating range for the machinery and the safe operating speed
• This function is executed with the Servo Driver in Servo ready status. It cannot be executed while
• If the Servo ON command is ON, turn it OFF.
• If user parameter Pn50A.1 is set to 7 and Servo-ON is selected to be always enabled, clear the
• The mode during program JOG operation is the position control mode, but pulse command inputs
• The overtravel function is disabled in JOG mode, but it is enabled for program JOG operation.
• The SEN signal is always enabled when an absolute encoder is used.
• Functions such as position command filters, that can be used for position control, can be used.
• This function cannot be executed when Pn200.2 is set to 1 (Deviation counter not reset when Servo
4-92
Operation
Pn530.0
Pn531
Pn533
Pn534
Pn535
Pn536
in user constants such as the program JOG movement distance and the program JOG movement
speed.
the Servo is ON.
always enabled setting for the Servo-ON signal.
to the Servo Driver are prohibited and not received.
is OFF).
Parameter
Parameters Requiring Settings
Precautions
No.
Program JOG opera-
tion related switches --
Program JOG operat-
ing pattern
Program JOG move-
ment distance
Program JOG move-
ment speed
Program JOG acceler-
ation/deceleration time
Program JOG waiting
time
Number of program
JOG movements
Parameter name
Set the program JOG operating pattern.
Set the program JOG movement distance.
Setting range: 1 to 1,073,741,824 (command
units)
Sets the program JOG movement speed.
Setting range: 1 to 10,000 (r/min)
Set the acceleration/deceleration time for pro-
gram JOG operation.
Setting range: 2 to 10,000 (ms)
Set the program JOG waiting time (the time that
the Servomotor is to be stopped).
Setting range: 0 to 10,000 (ms)
Sets the number of repetitions of the operating
pattern set in Pnn530.0, under the conditions
set in Pn531 to Pn535.
Setting range: 1 to 1,000 (times)
Explanation
4-3-3 Parameter
Details
4-3-3 Parameter
Details
4-3-3 Parameter
Details
4-3-3 Parameter
Details
4-3-3 Parameter
Details
4-3-3 Parameter
Details
Chapter 4
Reference

Related parts for R88M-W75030T-S1