2-4-3 Terminal Block Specifications
2-56
Standard Models and Specifications
DRV alarm 0
DRV alarm 1
DRV alarm 2
Internal command error
Missing phase detected
L1
L2
L3
L1C
L2C
B2
B3
U
V
W
B1/ +
B1/ +
− 1
− 2
Symbol
Error detection function
Main circuits power
supply input
DC Reactor terminal
for power supply har-
monic control
Main circuit positive
terminal
Main circuit negative
terminal
Control circuits power
supply input
External regeneration
resistance connection
terminal
Servomotor connec-
tion terminals
Frame ground
Function
Servo Driver DRV error 0 occurred.
Servo Driver DRV error 1 occurred.
Servo Driver DRV error 2 occurred.
A command error occurred in the Servo Driver.
One phase from the three-phase main circuit power supply is not connect-
ing.
R88D-WN@H-ML2 (50 to 400 W):
Single-phase 200/230 VAC (170 to 253 V), 50/60 Hz (No L3 terminal)
R88D-WN08H-ML2 (750 W):
Single-phase 200/230 VAC (170 to 253 V), 50/60 Hz
Note: The L3 terminal is not used, so do not connect it.
R88D-WN@H-ML2 (500 W to 3.0 kW):
Single-phase 200/230 VAC (170 to 253 V), 50/60 Hz
R88D-WN@L-ML2 (50 to 400 W):
Single-phase 100/115 VAC (85 to 127 V), 50/60 Hz (No L3 terminal)
R88D-WN@H-ML2 (500 W to 3.0 kW)
Normally short-circuit between − 1 and − 2.
If harmonic control measures are required, connect a DC Reactor
between − 1 and − 2.
Used for DC power supply input.
The R88D-WN@H-ML2 (500 W to 3.0 kW) does not have a − terminal.
Use the − 2 terminal.
R88D-WN@H-ML2: Single-phase 200/230 V AC (170 to 253 V AC)
50/60 Hz
R88D-WN@L-ML2: Single-phase 100/115 V AC (85 to 127 V AC)
50/60 Hz
R88D-WN@H-ML2 (50 to 400 W)
R88D-WN@L-ML2 (50 to 400 W)
This terminal does not normally need to be connected. If regenerative
energy is high, connect an External Regeneration Resistor between B1
and B2. (There is no B3 terminal.)
R88D-WN@H-ML2 (500 W to 3.0 kW)
Short-circuit between B2 and B3. If regenerative energy is high, remove
the short bar between B2 and B3 and connect an External Regeneration
Resistor between B1 and B2.
Red
White
Blue
Green/
Yellow
This is the ground terminal. Ground to a minimum of 100 Ω (class-3).
These are the terminals for outputs to the Servomotor. Be
sure to wire these terminals correctly.