R88M-W75030T-S1 Omron, R88M-W75030T-S1 Datasheet - Page 364

no-image

R88M-W75030T-S1

Manufacturer Part Number
R88M-W75030T-S1
Description
SERVO MOTOR 750W 200V
Manufacturer
Omron
Datasheet

Specifications of R88M-W75030T-S1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88MW75030TS1
5-32
Troubleshooting
a.e61
a.ea0
a.ea1
a.ea2
a.ed0
a.f10
Display
MECHATROLINK-
II transmission
cycle error
DRV alarm 0
DRV alarm 1
DRV alarm 2
Internal command
error
Missing phase
detected
Error
Occurs during
MECHATROLINK-
II communications.
Occurs when the
control circuit
power supply is
turned ON or dur-
ing operation.
Occurs when
MECHATROLINK-
II communications
are started, or dur-
ing operation.
Occurs when the
control circuit
power supply is
turned ON.
Occurs when the
main circuit power
supply is turned
ON.
Occurs during Ser-
vomotor drive.
Status when
error occurs
• The MECHATROLINK-II
• Servo Driver is defective. • Replace the Servo
• Servo Driver is defective. • Replace the Servo
• Parameters were edited
• Servo Driver is defective. • Replace the Servo
• Servo Driver is defective. • Replace the Servo
• The three-phase power
• The three-phase power
• Servo Driver is defective. • Replace the Servo
• There are faulty contacts
• The three-phase power
• Servo Driver is defective. • Replace the Servo
transmission cycle fluctu-
ated.
at a personal computer
during MECHATROLINK-
II communications.
supply is faulty.
supply is unbalanced.
in the three-phase power
supply wiring.
supply is unbalanced.
Cause of error
• Eliminate the cause of
• Do not edit parameters
• Correct the power supply
• Correct the power supply
• Correct the power supply
• Correct the power supply
fluctuation in the host
device transmission
cycle.
Driver.
Driver.
during MECHATROLINK-
II communications.
Driver.
Driver.
wiring.
unbalance. (Switch the
phase.)
Driver.
wiring.
imbalance.
Driver.
Countermeasures
Chapter 5