Operation
Note Refer to 4-3-2 Important Parameters.
Setting Explanation
• Select setting 1 if using a DC power supply.
• If using a DC power supply, perform the following operations.
Note 1. Always set this parameter to 1 when using a DC power supply. If a DC power supply is con-
Note 2. If using a DC power supply, the regeneration absorption circuit inside the Servo Driver will
Note 3. If using a DC power supply, the residual voltage in the main-circuit power supply is not dis-
Note Do not change setting.
Pn001.1
Setting
range
Pn001.2
Setting
range
0
1
Pn001.3
Setting
range
Setting
Control circuit power supply: Supply DC power to L1C and L2C. There is no polarity.
Main circuit power supply: Supply DC power as follows: Positive voltage to B1/ 1 terminal, and
ground to
External regeneration resistance terminals: Remove the short bar from between B2 and B3 so that
B1, B2, and B3 are open. (For Servo Drivers without B3, open B1 and B2.)
Use 270 to 320 VDC as the input voltage. (100-V input models do not handle DC inputs.)
nected with this parameter set to 0, the regeneration absorption circuit will operate, possibly
damaging the Servo Driver. When changing the setting from 0 to 1, either the main circuit
power supply must be OFF, or the external regeneration resistance terminals must be open.
not operate. The regeneration power returns to the DC power supply, so make sure the DC
power supply can absorb the regeneration power.
charged rapidly when the power is turned OFF. Be sure to mount a discharge circuit on the
DC power supply. Also, check that the charge indicator is not lit before storing the power sup-
ply input when the power supply has been turned OFF (the discharge time for the Servo
Driver is approximately 30 minutes.)
AC power supply: AC power supplied from L1, L2, (L3) terminals
DC power supply input: DC power from B1/
nals.
Function selection application switches 1 -- Stop selection when drive prohibited is input (Posi-
tion, speed)
0 to 2
Function selection application switches 1 -- AC/DC power input selection (All operation modes)
0, 1
Function selection application switches 1 -- Not used.
---
or
2 terminal.
Unit
Unit
Unit
---
---
---
Explanation
Default
setting
Default
setting
Default
setting
+
,
terminals, or DC power from B1/
0
0
0
Restart
power?
Restart
power?
Restart
power?
+
Chapter 4
+
Yes
Yes
Yes
,
2 termi-
4-33